Multifunctional acoustic elimination shutter ,acoustic elimination Louvers,Exhaust Noise elimination Louvers made in China

본문 바로가기


Home > Product > Multifunctional acoustic elimination shutter ,acoustic elimination Louvers,Exhaust Noise elimination Louvers made in China
Product
Multifunctional acoustic elimination shutter ,acoustic elimination Lou...
Posting date : Jan 05, 2017
Membership
Free Member Scince Jan 05, 2017
FOB Price
40-300Dollar
Min. Order Quantity
1 cubic meter
Supply Abillity
2000 cubic meter/month
Port
Shanghai
Payment Terms
L/C,T/T
Package
The equipment is packed with foam then fix into a custom wooden box
Keyword :
Category
Contact
David Zeng
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
ZISEN
HS-CODE
8529-10
Package & Delivery Lead Time
Package
The equipment is packed with foam then fix into a custom wooden box
Detailed Description

Sound Elimination Louver contain Arc Sound Elimination Louver and Oblique Sheet Type Sound Elimination Louver.

Arc sound elimination louver is riveted with upper and lower sound absorber, arc sound absorber and side plate, and sound absorber is the pore plate externally wrapped with melamine and other sound absorption materials. Arc sound elimination louver is applicable to various air vents of plants.

Arc sound absorber adopts oval louvre blade design, and has small ventilation resistance, and upper blade can prevent the entry of rainwater, and lower blade can effectively absorb the noise; it is characterized by fireproof, rainproof and dampproof property and good-looking appearance. 

 

Oblique sheet type sound elimination louver is riveted with upper and lower sound absorber, oblique sheet sound absorber and side plate, and sound absorber is the pore plate externally wrapped with melamine and other sound absorption materials. Oblique sheet type sound elimination louver is applicable to various air vents of plants.

Oblique sheet type sound absorber adopts rhombic louvre blade design, and its ventilation resistance is larger than that of arc sound elimination louver, and sound elimination effect is better than that of arc sound elimination louver. Upper blade can prevent the entry of rainwater, and lower blade can effectively absorb the noise; it is characterized by fireproof, rainproof and dampproof property and good-looking appearance.

 

1. For commercial buildings and industrial plants, large air flow must be taken into account, and these airs are used for cooling and supplying air compressor or generator, and for ventilation and air conditioning system.

2. In many ventilation systems, the equipment will make strong noise while producing airflow, so the problems encountered by designers and engineers are to allow ventilation, and prevent the transmission of noise outwards. Especially lower pressure drop requirements and effective noise prevention requirements are very important evaluation standards. At the meantime, the economy, good-looking appearance and practicability as required by architect should also be taken into account.

3. Air vent of factory workshop, air inlets of cooling tower, compressor room, power station, substation, exhaust chamber, diesel engine unit room, parking lot, air conditioning unit, natural ventilation area and condensing unit, air inlet and outlet window of equipment room, ventilation & heat dissipation window of sound insulation hood of strong noise equipment, and local air vent of sound barrier.

Standard design, multiple models, dimensions and exterior finishes are suitable for all industrial and commercial engineering projects with ventilation and noise reduction requirements.

The sound elimination quantity of 300 type arc sound elimination louver produced by our company is 8-12dB(A), and when the flow per square meter is 1800m3/h~3600m3/h, airflow speed between blades is 1~2m/s, and pressure loss is ≤15Pa. 

If the arc louver with higher sound elimination quantity is required, it can increase or decrease the thickness per 300 mm, and improve the sound elimination quantity of sound elimination louver. 

Equipment Name

Property Features 

Application Scope

Arc sound elimination louver

Sound elimination quantity of arc sound

 elimination louver is 8~12dB(A)

Applicable to outer wall sound elimination

 projects with lower sound elimination quantity

 requirements and higher appearance requirements

 

The sound elimination quantity of 300 type oblique sheet type sound elimination louver produced by our company is 8-15dB(A), and when the flow per square meter is 1800m3/h~3600m3/h, airflow speed between blades is 1~2m/s, and pressure loss is ≤20Pa.

If the oblique sheet type sound elimination louver with higher sound elimination quantity is required, it can increase or decrease the thickness per 300 mm, and improve the sound elimination quantity of sound elimination louver.

Product Features

Acoustic:Sound elimination quantity is 8~15dB (A)

Environmental protection: free of harmful substances 

Burning grade: grade A non-flammable GB8624-2012

Easy to install 

25-year service life

External surface can be sprayed 

Customizable 

 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea