YOKOGAWA UT37

본문 바로가기


Home > Product > YOKOGAWA UT37
Product
YOKOGAWA UT37
Posting date : Jan 12, 2015
Membership
Free Member Scince Dec 15, 2014
FOB Price
100
Min. Order Quantity
1
Supply Abillity
20000
Port
SHENZHEN
Payment Terms
TT
Package
box
Keyword :
Category
Contact
liu
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
Japan [JP]
Brand Name
YOKOGAWA
Model Number
DCS
HS-CODE
8542-31
Package & Delivery Lead Time
Package
box
Delivery Lead Time
6days
Detailed Description
Yokogawa UT37 UT37E Digital Indicating Controller comes with what you see in the pictures. If you don't see it, you probably won’t get it. Specifications are from manufacturer and may vary slightly due to upgrades, options, or revisions this unit may or may not have. 
Discontinued – Replaced by UT4501 or UT551-1 
Suggested List Price: $700.50 (OEM 04/30/09 MQF) 
Model Number: UT37E (w/ hardware) 
Serial Number : N/A 
Electrical : 100-240VAC, 50/60Hz 
Includes Hardware 
Copy of User Manual & Calibration Instructions Included 
Product Description: The U37 digital indicating controller uses a universal input/output system. The UT37 is a highly accurate and sophisticated, easy-to-operate digital indicating controller with an input sampling period of 200ms and measurement accuracy of +0.2%. 
Features: 
Universal input/output system Simple operations (using four keys) Compact Size (96 x 96 x 100mm) SUPER function Coordinated operation 
Specifications: 
Input Sampling Period: 200ms Input Accuracy: ±0.2 (or ±0.25%) of F.S. ±1 digit Input Resistance: Thermocouple Input: 1M ohm or more; Voltage Input Approx: 1M ohms Permissible Signal Source Resistance: Thermocouple: 250 ohms or less; Voltage: 2K ohms or less Permissible Wiring Resistance: RTD Input: 10 ohms or less/wire Permissible Input Voltage: Thermocouple, DC Voltage/Current Input: Within ±10V Noise Rejection Ratio: Normal Mode: 40dB (50/60Hz) or more; Common Mode: 120dB (50/60Hz) or more Filter: OFF, 1 to 120 sec (first order lag. OFF: no filter) Measured Input Bias: -100.0 to 100% of measuring span Thermocouple Standards: IEC/DIN (U and L)/JIS RTD Standards: IEC/DIN/JIS ’89 JPT100, PT100 Display Contents: Process Variable (PV), Setpoint/Parameter, Status Lamps (6) Process Variable Display: 4-digit, 7-segment LEDs (red) Setpoint or Parameter Display: 3-digit 4-digit, 7-segment LEDs (red) Deviation Monitor: Green LED lights when deviation is within ±1.0 of F.S. If deviation exceeds this range, Orange LED lights. Measured Input: Within instrument range Target Value (setpoint): 0 to 100% of the range Setpoint High and Low Limits: 0 to 100% of the range Proportional Band (P): 0.1 to 999.9% Integral Time (I): OFF, 1 to 6000sec (OFF: Integral action is OFF) Derivative Time (D): OFF, 1 to 6000sec (OFF: Derivative action is OFF) Thermocouple Input: 1°C to 0.1°C (1°F or 0.1°F) RTD Input: 0.1°C (0.1°F) Number of Selectable Setpoints: 2 Number of PID Settings: 2 (to be set for each setpoint) Setpoint Selection: Voltage-free remote contact (External contact rating: 12VDC or more, 10mA or more) Output Type: Time proportional PID (relay output); Time proportional PID (voltage pulse output for driving external SSR); Continuous output PID (4 to 20mA DC output); ON/OFF (relay output) Relay Output Contact Rating: 250VAC, 3A (resistive load) Voltage Pulse Output: ON Voltage: Approx. 12VDC or more (load resistance: 60 ohms or more); OFF Voltage: 0.1VDC or less 4 to 20mA DC Output: Load resistance of 600 ohms or less, accuracy of ±0.3% of F.S.; output updating period of 200ms Cycle Time: 1 to 240sec (relay and voltage pulse output) Output High and Low Limits: -5 to 105% Setting Alarm Function Content: Process variable high and low limits, deviation high and low limits, etc. (selectable for each point from among 20 types. Timer function can be specified) Alarm Value: 0 to 100% of the set range Number of Alarm Settings: 2 Alarm Output: Relay output contact rating: 250VAC, 1 (resistive load) Display: LED lamp display on the front panel Operating Ambient Temperature: 0 to 50°C Operating Ambient Humidity: 20 to 90% R.H. (non-condensing) Operating Temperature Compensation Error: 0 to 50°C: ±1°C Magnetic Field: 400 AT/m or less Warm-Up Time: 30 min or more Ambient Temperature Effect: Input stability: within (±1uV/°C or ±0.01°C, whichever is greater); Output stability: within (4 to 20mA DC) ±0.05%/10V) Power Supply Variation: Input stability: within (±1uV/10V or ±0.01°C, whichever is greater); Output stability: within (4 to 20mA DC) ±0.05%/10V) Storage Temperature: -25 to 70°C Storage Humidity: 5 to 95% R.H. (non-condensing) Construction: Dustproof, drip-proof construction (front panel) Mounting: Flash mounting Case: Plastic molding (ABS resin) Dimensions: 96W x 96H x 100D mm Weight: Approx. 1kg Insulation Resistance: Between each terminal and ground: 20M ohms or more at 500VDC Withstand Voltage: Between power terminals and ground: 1500VAC for 1min; Between input terminals and ground: 1000VAC for 1min; Between output terminals and ground: 1500VAC for 1min Supply Voltage: 100 to 240VAC (universal power supply) (permissible supply voltage rang: 90 to 250VAC) Power Frequency: 50/60Hz common Power Consumption: Approx. 12A (100V) Memory Protection: Nonvolatile memory 