Global Trade leader ecrobot

본문 바로가기


Home > Product > MISCELLANEOUS > | Optical photographic cin | Oscilloscopes spectrum a
Products 185 Result
GSM 3G temperature monitoring device S260
May 30 2016
Model: S260  S261 Name: GSM GPRS 3G Temperature Logger The GSM GPRS 3G Temperature Logger is special for remote monitoring temperature. it can setup ultra-high—high, low…
HS-CODE : 9030-32
King Pigeon GSM 3G Telem...
China [CN]
Scince 2005
Free Member
Meeteasy Mini Analog conference phone with USB
May 21 2016
Features: Suitable for small group conferencing calls up to 8-10 persons High sensitive microphones provide 360° audio pickup over 3m Superb full duplex bi-directional conversation…
HS-CODE : 9030-40
Meeteasy technology limi...
Hong Kong [HK]
Scince 2014
Free Member
60-100meters telecom lattice steel tower
Nov 05 2015
1. Design Criteria of Steel Tower1.1 Basic wind speed:40m/s, 42m/s, 45m/s (3 second gust)1.2 Exposure Category C and Topographic Category 2_50m crest height1.3 Code: ANSI/TIA/EIA-222-G Latest1.4 Max A…
HS-CODE : 9030-40
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
60,70,80,90meters angular lattice steel tower
Nov 05 2015
Why choose us? because:a. As a intergraded solution provider in telecommunication infrastructure field over 80 years, not only do we supply telecom steel tower for client, but also we provide design…
HS-CODE : 9030-89
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
40-120meters self supporting telecom tower
Nov 05 2015
1. Design Criteria of Steel Tower 1.1 Max wind velocity:40m/s, 42m/s, 45m/s(3 second gust) 1.2 Exposure Category C and Topographic Category 2_300m crest height 1.3 Code: ANSI/TIA/EIA-222-G …
HS-CODE : 9030-89
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
60,70,80,90meters self supporting lattice steel tower
Nov 05 2015
1. Design Criteria of Steel Tower 1.1 Basic wind speed=100mph (3 second gust) 1.2 Exposure Category C and Topographic Category 1 1.3 Code: ANSI/TIA/EIA-222-G Latest 1.4 Antenna load: light…
HS-CODE : 9030-84
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
60&70meters four legs telecommunication tower
Nov 05 2015
Tower specification as following:1. Design Criteria of Steel Tower 1.1 Basic wind speed=40m/s, 42m/s, 45m/s(3 second gust) 1.2 Exposure Category C and Topographic Category 3_300m cre…
HS-CODE : 9030-40
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
70meters square lattice GSM tower
Nov 05 2015
Why choose us? because:a. As a intergraded solution provider in telecommunication infrastructure field over 80 years, not only do we supply telecom steel tower for client, but also we provide design…
HS-CODE : 9030-89
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
60meters lattice tower for MIC telecom project
Nov 05 2015
Why choose us? because:a. As a intergraded solution provider in telecommunication infrastructure field over 80 years, not only do we supply telecom steel tower for client, but also we provide design…
HS-CODE : 9030-89
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
35,40,50,60meters telecommunication angular tower
Nov 05 2015
1. Design Criteria of Steel Tower 1.1 Basic wind speed:40m/s, 42m/s, 45m/s (3 second gust) 1.2 Exposure Category C and Topographic Category 2_50m crest height 1.3 Code: ANSI/TIA/EIA-222-G L…
HS-CODE : 9030-40
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
100meters four legs commnication tower
Nov 05 2015
Why choose us? because:a. As a intergraded solution provider in telecommunication infrastructure field over 80 years, not only do we supply telecom steel tower for client, but also we provide design &…
HS-CODE : 9030-84
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
120meters self supporting square steel tower
Nov 05 2015
Why choose us? because:a. As a intergraded solution provider in telecommunication infrastructure field over 80 years, not only do we supply telecom steel tower for client, but also we provide design…
HS-CODE : 9030-84
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
45meters telecommunication lattice steel tower
Nov 05 2015
1. Design Criteria of Steel Tower 1.1 Basic wind speed=150mph (3 second gust) 1.2 Exposure Category C and Topographic Category 1 1.3 Code: ANSI/TIA/EIA-222-G and ANSI/ASEC 10-97 Latest 1…
HS-CODE : 9030-40
Global Tower Engineering...
China [CN]
Scince 2012
Free Member
USKY Skype SIP Gateway without PC for PBX/IPPBX, VOIP Gateway, SIP Ser...
Oct 21 2015
1.USKY Skype SIP Gateway as a VOIP Gateway, perfectly connect with original PBX(telephone system) or IPPBX, make or receive Skype calls through the desktop phone, no habits changed.   2.R…
HS-CODE : 9030-40
Union Professional Co., ...
Taiwan [TW]
Scince 2007
Free Member
MTP Trunk Cable Assemblies
Oct 15 2015
Overview Combining 12~144 fiber trunk cable with 12F MPO/MTP and generic connectors, Gigalight’s trunk cable assemblies contain MPO to MPO and MPO hybrid types. Plug and Play Reels, Pull…
HS-CODE : 9030-89
China Fiber Optics Techn...
China [CN]
Scince 2011
Free Member

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top