115KV dead end monopole tower
Posting date : Feb 25, 2014
Membership
Free Member Scince Feb 17, 2014
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
115KV DEAD END TOWER FOR POWER TRANSMISSION Dead-end tower, also named anchor tower or anchor pylon, uses horizontal strain insulators and occur at the endpoints of conductors. Such endpoints are necessary when interfacing with other modes of power transmission and, due to the inflexibility of the conductors, when significantly altering the direction of the tower line. Dead-end towers are also employed at branch points as branch pylons. A tower at which the power line runs further as overhead line and as underground cable is a branch tower for a cable branch. MEGATRO provide many types of 115KV dead end tower fro power transmission for our clients, which is widely use for oversea clients. 115KV dead end tower for power transmission is used for urban power grid, it is one good choice for city power transmission due to its less space, less time to install and are aesthetical in appearance, compared to conventional lattice tower. Monopole towers use a minimal space requirement, and with a solid and stable structure from which to add additional carriers. Till now, we had provided too many 115KV distribution and transmission pole for American market these years. MEGATRO is equipped with sophisticated machinery and equipment for the manufacture of monopole for 115KV power transmission line project, we have skilled worker with certificated welders, and offers a variety of monopole types to meet client specific. Tapered steel and flanged steel poles feature designs that blend well into the environment and require minimum space for installation. Flanged steel poles are easy to handle and install. Slip type with precision fitted connections allow quick assembly of sections and total poles seems uniform and harmony with environment, especially accept by our foreign clients. Pole sections are available with identical base flange plates, allowing for simplified modifications of mounting heights. In material we often adopt mild steel (ASTM A36, Q235B), high strength and lower alloy (ASTM A572 GR50, GR65, Q345B, Q345C, Q420, Q460, S355J0, S355JR and equivalent materials). MEGATRO can optimize design and adjust monopole size to make it less weight, solid strength and economic cost. After fabrication all towers are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. MEGATRO is one of the few manufactures who provide dead-end tower and assemble every tower section. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies. other information: Availability size: Based on the customer's requirements. Material: Chinese material or as per clients requirement Package: Both parties discuss before delivery Terms of Payment: L/C, T/T Minimum Order Quantity: 50tons Port of Loading: Qingdao Port Lead Time: One month or based on the customer's needs Performance Standard Besides conform to the drawing and design, the materials and fabrication of tower components shall conform to the Chinese Standard or other standard which clients can accept. 1. GB/T2694-2003 Transmission line tower - - Technical requirements for manufacturing 2. JGJ81-2002: Technical specification for welding for steel structure of building 3. GB9787-88: Measuring and allowable tolerance for hot-rolled equal angle 4. GB709-88: Measuring and allowable tolerance for hot-rolled plate and strip 5. GB/T699-1999: Quality Carbon Structural Steel 6. GB/T1591-1994: Low alloy high strength structural Steel 7. GB700-88: Carbon Structural Steel 8. GB222-84: Method of sampling steel for determination of chemical composition and permissible variations 9. GB/T228-2002: Method for Tensile testing of metals 10 GB/T232-1999: Method for Bending test of metals 11 GB/T5117-1995: Carbon Welding Rod 12 GB/T5118-1995: Low Alloy Welding Rod 13 GB/T8220-1995: Welding wires for gas shielding arc welding of carbon and low alloy steels 14 GB/T10045-2001: Carbon steel flux cored electrodes for arc welding 15 JB/T7949-1999: Weld outer dimensions for steel construction 16 GB50205-2001: Test Standard for Acceptance of Steel Structure 17 GB/T470-1997: Zinc Ingot 18 GB3098.1-2000: Mechanical properties of fasteners-Part 1: Bolts, screws and studs 19 GB3098.2-2000: Mechanical properties of fasteners-Part2: Nuts, and thread 20 GB3098.3-2000: Mechanical properties of fasteners-Part3: Fastening screw 21 GB/T5780-2000: Helical Bolts Grade C 22 GB/T41-2000: Helical Nuts Grade C 23 GB/T90-2002: Flat Washer Grade C 24 GB/T13912-2002: Metal Coating, Technical Requirement We also adopt British, American and other international standard which client can accept.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top