Quick Detail
Place of Origin
HS-CODE
84-
Package & Delivery Lead Time
Detailed Description
mine temperature sensor
Technical parameters:
1, Explosion-proof type:, mine intrinsically safe explosion-proof marks for ExibI;
2, Rated working voltage: 12 VDC;
3, Rated current: = < 35 mA;
4, Maximum input voltage Ui: 12.9 VDC;
5, Maximum input current Ii: 420 mA;
6, Maximum internal inductance Li: 0 mH;
7, Maximum internal capacitance, Ci: 4.8 uF;
8, Measuring range: 0-60 ℃, resolution: 1 ℃;
9, Overtemperature action: overtemperature output adjustable value within the range (37-60)℃, overtemperature action output error value: no more than plus or minus 2℃;
10, Output signal: switch quantity level signal;
A) When the temperature does not exceed "overtemperature action output value. The output: < = 0.5 V low level:
B) When the temperature exceeds "overtemperature action output value". Output: > = 6 v high level;
11, Response time: = < 5 s:
12, Power supply voltage fluctuation adaptability: when the input voltage fluctuate within 10 VDC - 15 VDC. Sensors should be positive
Often work;
13, Environment temperature: 0 ℃ and 40 ℃;
14, Average relative humidity: = < 95%;
15, Transmission distance: = < 100 m;
16, Connecting cable: coal mine use mobile rubber set soft cable connection. The connection length = < 100 m:
17 Associated equipment: ZP - 127z automatic sprinkler dust device for mine main box;
18, Temperature sensor shape dimension: 170(1300)×110×65(mm);
19. Weight: 2.5 kg.
Madery
Jining Hengwang Mining Machinery Co.,Ltd.
E-mail: maderyhengwang AT hotmail.com
Skype: maderyhengwang Mob: +86-13668679003