24V1.5A 36W ZF120A-2401500

본문 바로가기


Home > Product > 24V1.5A 36W ZF120A-2401500
Product
24V1.5A 36W ZF120A-2401500
Posting date : Apr 11, 2013
Membership
Free Member Scince Mar 12, 2013
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
84-
Package & Delivery Lead Time
Detailed Description
1、(SCOPE)24V1.5A36W: The purpose of the document is to specify the functional requirements of a 36W switching power supply. 2、(INPUT CHARACTERISTICS): 2.1 (Input Voltage): (Nominal Voltage):100-240Vac (Variation Range):90-264Vac 2.2(Input Frequency): (Nominal Frequency):50/60Hz (Variation Frequency):47-63Hz 2.3 (Input Current): 1Arms max At any input voltage and rated, DC output rated load. 2.4 (Inrush Current): 30Amps Max. Cold start at 240Vac input, with rated load and 25℃ambient. 2.5 (Ac Leakage Current): 25mA Max At 240Vac input. 3、(OUTPUT CHARACTERISTICS): 3.1 (Power Output); Voltage Min. Load Max. Load Peak Output Power +24Vdc 0A 1.5A 1.6A 36W 3.2 (Combined Load/Line Regulation): Voltage Min. Voltage Max. Voltage Line Regulation Load Regulation +24Vdc 24. 0V 25.2V ±5% ±5% 3.3(Ripple And Noise): The ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point. Voltage Ripple And Noise(Max.) +24Vdc 130.5mVp-p 3.4 (Turn On Delay Time): 2 second Max. At 115Vac input and output Max. Load. 3.5 (Rise Time): 40mS Max. At 115Vac input and output Max. Load. 3.6 (Hold Up Time): 5mS Min. At 115Vac input and output Max. Load. 3.7 (Efficiency): 80%Min.At 100Vac input and output Max. Load. 83%Min.At 240Vac input and output Max. Load. 3.8 (Overshoot): 15%Max.When power supply at turn on or turn off. 3.9 No-load loss is not more than 0.5W . 4、 (PROTECTION REQUIREMENT): 4.1Short Circuit Protection: The power supply will be auto recovered when short circuit faults remove. 4.2 (Over current Protection):The power supply will be auto recovered when over current faults remove. 4.3 (Over Voltage Protection) The power supply will not be auto recovered when faults remove. 5、 (ENVIRONMENTAL REQUIREMET): 5.1 (Operating Temperature): 0℃to40℃,Full load Normal operation. 5.2 (Storage Temperature):-20℃to85℃, (With package). 5.3 (Relative Humidity):5%(0℃)~90%(40℃)RH,72Hrs,Full load Normal operating. 5.4 (Vibration): 1、Operating: IEC 721-3-3 3M3 5~9Hz,A=1.5mm(9~200Hz,Acceleration 5m/s2) 2、(Transportation): IEC 721-3-2 2M2 5-9Hz,A=3.5mm 9~200Hz, Acceleration=5m/S2 200~500HZ, Acceleration=15m/S2 3、(Axes,10 cycles per axis).No permanent damage may occur during testing. 4、The product has to restors its original situation after power off/on.) 5.5 (Dropping)(Packed):1 corner,3 edges, and 6 surfaces Height:76cm 6、 (SAFETY AND EMC REQUIREMENT): 6.1 Match Standard with UL CE GS SAA ROHS 6.2 (DIELECTRIC STRENGTH)(H-Pot): (Primary to secondary),3000Vac/5mA/60s. 7、 (MECHANICAL REQUIREMENT): 7.1 (Enclosure):The power supply size L: 119*52*34MM 7.2 (Input Connector): 7.3;Output DC cable: AWM 1185 20AWG*2C,VW-1,80℃,FTI,300V,with word on the cord, Length:1.2M, with the conector:5.5*2.5 8、(Label): Material: PVC Endure heat above110℃ Thickness:0.2-0.3mm 3*RI±0.1mm 3*RI±0.1mm Angle 2.5mm 9、PACKING White inner box+out carton White inner box out side dimension LxWxH(195x85x75) Tolerance:±3

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top