High frequency online ups Key features: 1.True on-line double conversion technology with advanced microprocessor control 2.115~300VAC input range 3.Zero transfer time 4.Protection against all types of power problems 5.Self test while start UPS 6.Site wiring fault warning 7.On-battery power-on function 8.Smart RS232 communication interface 9.Intelligent slot available Technical specifications: Model 1KRS(L) 2KL 3KL 6KL Rated power VA/W 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW 6KVA/4.2KW Input Nominal voltage 220VAC Voltage range 115~300VAC 176~276VAC Frequency range 46~54Hz(default), user adjustable within 40~60Hz 46~54Hz Power factor 0.97 0.98 Connection IEC320-10A inlet IEC320-16A inlet Terminal block Output Voltage 220VAC±2% 220VAC±1% Frequency 46~54Hz or 50Hz±0.2Hz(line mode) 50Hz±0.2Hz(battery mode) 46~54Hz(line mode) 50Hz±0.05Hz(battery mode) Waveform Pure sine wave Overload capability 108%~150% for 30 sec., 150% for 300 ms 105%~130% for 10 min., 130% for 1 min. Current crest ratio 3:1 Bypass Automatic transfer On overload and UPS failure Before UPS power-on Default “NO”, user adjustable to “YES” Yes Voltage range 80~264VAC(default), user adjustable within 80~286VAC 176~261VAC Output connections IEC320-10A*4 IEC320-10A*4 IEC320-10A and terminal block IEC320-10A*4 and terminal block Transfer time 0 ms; less than 4 ms from inverter to bypass and vice versa Zero LED indicators Status Load level/battery level, battery, utility power, inverter, bypass, overload, fault Audible alarm Bypass, on battery mode, battery low, overload, fault Communications RS-232 serial interface Intelligent slot; Options: WebPower SNMP/Web card, AS400 card or WinPower CMC Network surge protection RJ45 I/O port available for network or fax/modem Environmental Operating temperature 0~40°C Operating humidity 20~90% non-condensing Main unit Net weight(Kg) 15.3 10.3 11.2 18.3 Dimensions(W x D x H) mm 482.6x450x88(2U) 482.6x600x130(3U) Battery pack Type Internal batteries External battery pack Nominal DC voltage 36VDC 96VDC 240VDC Backup time (full load) 5 min 9 min(with 1 BP) 5 min(with 1 BP) 7 min(with 1 BP) Gross weight(Kg) 16 25.6 58.2 Dimensions(Wx DxH) mm 482.6x450x88(2U) 482.6x600x130(3U)

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top