Toxic gas alarm

본문 바로가기


Home > Product > Toxic gas alarm
Product
Toxic gas alarm
Posting date : Oct 10, 2012
Membership
Free Member Scince Oct 10, 2012
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
84-
Package & Delivery Lead Time
Detailed Description
Model OEM Gas Meter with temperature and humidity Model OEM series intelligent temperature humidity gas analyzer is my company design and development of a high performance, multifunction gas detector; designed for the CDC, indoor and outdoor air quality monitoring for the design of a high performance gas measuring instrument, with 5minutes,15minutes,30 minutes, 1 hour, 8 hours, 24hours mean value function, more suitable for air quality monitoring and assessment. At the same time, increased the precision of temperature and humidity measurement function, provides a toxic gas, oxygen, combustible gas up to dozens of different type of gas range, more suitable for the disease control, health, environment monitoring station, gas, safety protection, plant, landfill, biological, pharmaceutical, food hygiene and other gas detection and monitoring. Characteristics of innovation: 1、Portable 2、Rechargeable Battery, Low battery indication, 3、Adjustable sound and light alarm 4、Temperature and humidity measurement. 5、Time and date settings 6、Average value 7、Zero Calibration 8、Removable/replaceable sensor head 9、Optional external pump Model Gas Sensor Calibrated Range/ppm Maximum Exposure Resolution Accuracy Response Time (T90) Sensor Life OEM NH3 Meter 0-100 200 0.1 ±5%F.S. < 60S > 2 years NH3 Meter 0-1000 2000 4 ±5%F.S. < 60S > 2 years AsH3 Meter 0-5 10 0.01 ±5%F.S. < 60S > 2 years Br2 Meter 0-20 200 0.1 ±5%F.S. < 90S > 2 years CO Meter 0-200 400 0.1 ±5%F.S. < 40S > 3 years CO Meter 0-1000 2000 1 ±5%F.S. < 40S > 3 years CO Meter 0-1% NoDate 5 ±5%F.S. < 40S > 3 years C3H4O Meter 0-100 200 1 ±5%F.S. < 60S > 2 years CLO2 Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years C3H3N Meter 0-100 200 1 ±5%F.S. < 60S > 2 years CH3COOC2H5 Meter 0-100 200 1 ±5%F.S. < 60S > 2 years CL2 Meter 0-20 200 0.1 ±5%F.S. <90S > 2 years CL2 Meter 0-200 400 1 ±5%F.S. <90S > 2 years CL2 Meter 0-5000 25000 25 ±5%F.S. <90S > 2 years ETO Meter 0-20 100 0.1 ±5%F.S. <140S > 2 years C2H4 Meter 0-10 100 0.01 ±5%F.S. < 60S > 2 years C2H4 Meter 0-200 500 0.5 ±5%F.S. < 60S > 2 years C2H4 Meter 0-1500 3000 4 ±5%F.S. < 60S > 1 years C2H4 Meter 0-10 50 0.01 ±5%F.S. < 60S > 3 years C2H4 Meter 0-100 200 0.1 ±5%F.S. < 50S > 3 years C7H8 Meter 0-10 20 0.01 ±5%F.S. < 50S > 2 years C7H8 Meter 0-100 200 0.1 ±5%F.S. < 50S > 2 years C5H8O2 Meter 0-20 20 0.01 ±5%F.S. < 60S > 2 years COCl2 Meter 0-5 50 0.01 ±5%F.S. < 60S > 1 years CH4 Meter 0-100%Lel 0-100Lel 1% ±5%F.S. <50S > 5 years F2 Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years GeH4 Meter 0-100 200 1 ±5%F.S. < 60S > 2 years HCL Meter 0-20 20 0.1 ±5%F.S. < 60S > 2 years HCL Meter 0-200 NoDate 1 ±5%F.S. < 60S > 2 years HCL Meter 0-1000 NoDate 5 ±5%F.S. < 60S > 2 years HCL Meter 0-3000 NoDate 6 ±5%F.S. < 60S > 2 years HCN Meter 0-100 1000 0.1 ±5%F.S. < 20S > 2 years HBr Meter 0-30 100 0.1 ±5%F.S. < 60S > 2 years H2 Meter 0-1000 2000 1 ±5%F.S. <50S > 2 years H2 Meter 0-2000 4000 3 ±5%F.S. <50S > 2 years H2 Meter 0-5000 1% 5 ±5%F.S. < 45S > 2 years H2S Meter 0-50 500 0.01 ±5%F.S. < 60S > 2 years H2S Meter 0-200 500 0.25 ±5%F.S. < 60S > 2 years H2S Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years H2S Meter 0-2000 3000 2 ±5%F.S. < 25S > 3 years HF Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years NO Meter 0-25 NoDate 0.15 ±5%F.S. < 25S > 3 years NO Meter 0-100 NoDate 0.5 ±5%F.S. < 25S > 2 years NO2 Meter 0-20 200 0.1 ±5%F.S. < 60S > 2 years N2H4 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years NF3 Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years NaH Meter 0-100 200 1 ±5%F.S. < 60S > 2 years O2 Meter 0-25% 30% 0.1% ±0.1% < 6S > 3years O3 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years O3 Meter 0-20 50 0.02 ±5%F.S. < 60S > 2 years O3 Meter 0-100 200 0.06 ±5%F.S. < 60S > 2 years O3 Meter 0-200 400 0.1 ±5%F.S. < 60S > 2 years O3 Meter 0-1000 2000 0.3 ±5%F.S. < 60S > 2 years POCL3 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years PCL3 Meter 0-100%lEL 100% 1% ±5%F.S. < 60S > 2 years PH3 Meter 0-5 25 0.01 ±5%F.S < 25S > 2 years PH3 Meter 0-500 1000 0.5 ±5%F.S < 25S > 2 years PH3 Meter 0-1000 2000 1 ±5%F.S < 25S > 2 years PH3 Meter 0-2000 4000 2 ±5%F.S < 25S > 2 years SO2 Meter 0-20 100 0.1 ±5%F.S. < 25S > 2 years SO2 Meter 0-100 500 0.5 ±5%F.S. < 25S > 2 years SO2 Meter 0-2000 4000 1 ±5%F.S. < 25S > 2 years SF6 Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years SiH4 Meter 0-20 Nodate 0.1 ±5%F.S. < 60S > 2 years SiH4 Meter 0-50 Nodate 0.2 ±5%F.S. < 60S > 2 years THT Meter 0-100 200 1 ±5%F.S. < 60S > 2 years TVOC(PID) Meter 0-20 50 0.2 ±5%F.S. < 20S > 5years TVOC(PID) Meter 0-200 500 0.1 ±5%F.S. < 20S > 5 years TVOC(PID) Meter 0-2000 5000 1 ±5%F.S. < 20S > 5 years Humidity (CH4 Meter Without this function) 10%-95%RH, Resolution :0.1%RH,Accuracy::± 3% R.H. Temperature(CH4 Meter Without this function) -20~80℃, Resolution : 0.1℃, Accuracy::±0.3℃ Average value 15min,1h,8h,24h Rechargeable battery pack DC3.7V, 800mA Size 150mmX36mmX65mm Weight About380g Power supply DC5V,500mA Approvals CE ※:Special gas can be customized。

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top