Quick Detail
Place of Origin
HS-CODE
84-
Package & Delivery Lead Time
Detailed Description
Model OEM Gas Meter with temperature and humidity
Model OEM series intelligent temperature humidity gas analyzer is my company design and development of a high performance, multifunction gas detector; designed for the CDC, indoor and outdoor air quality monitoring for the design of a high performance gas measuring instrument, with 5minutes,15minutes,30 minutes, 1 hour, 8 hours, 24hours mean value function, more suitable for air quality monitoring and assessment. At the same time, increased the precision of temperature and humidity measurement function, provides a toxic gas, oxygen, combustible gas up to dozens of different type of gas range, more suitable for the disease control, health, environment monitoring station, gas, safety protection, plant, landfill, biological, pharmaceutical, food hygiene and other gas detection and monitoring.
Characteristics of innovation:
1、Portable
2、Rechargeable Battery,
Low battery indication,
3、Adjustable sound and light alarm
4、Temperature and humidity measurement.
5、Time and date settings
6、Average value
7、Zero Calibration
8、Removable/replaceable sensor head
9、Optional external pump
Model Gas Sensor Calibrated Range/ppm Maximum
Exposure Resolution Accuracy Response Time (T90) Sensor Life
OEM NH3 Meter 0-100 200 0.1 ±5%F.S. < 60S > 2 years
NH3 Meter 0-1000 2000 4 ±5%F.S. < 60S > 2 years
AsH3 Meter 0-5 10 0.01 ±5%F.S. < 60S > 2 years
Br2 Meter 0-20 200 0.1 ±5%F.S. < 90S > 2 years
CO Meter 0-200 400 0.1 ±5%F.S. < 40S > 3 years
CO Meter 0-1000 2000 1 ±5%F.S. < 40S > 3 years
CO Meter 0-1% NoDate 5 ±5%F.S. < 40S > 3 years
C3H4O Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
CLO2 Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years
C3H3N Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
CH3COOC2H5 Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
CL2 Meter 0-20 200 0.1 ±5%F.S. <90S > 2 years
CL2 Meter 0-200 400 1 ±5%F.S. <90S > 2 years
CL2 Meter 0-5000 25000 25 ±5%F.S. <90S > 2 years
ETO Meter 0-20 100 0.1 ±5%F.S. <140S > 2 years
C2H4 Meter 0-10 100 0.01 ±5%F.S. < 60S > 2 years
C2H4 Meter 0-200 500 0.5 ±5%F.S. < 60S > 2 years
C2H4 Meter 0-1500 3000 4 ±5%F.S. < 60S > 1 years
C2H4 Meter 0-10 50 0.01 ±5%F.S. < 60S > 3 years
C2H4 Meter 0-100 200 0.1 ±5%F.S. < 50S > 3 years
C7H8 Meter 0-10 20 0.01 ±5%F.S. < 50S > 2 years
C7H8 Meter 0-100 200 0.1 ±5%F.S. < 50S > 2 years
C5H8O2 Meter 0-20 20 0.01 ±5%F.S. < 60S > 2 years
COCl2 Meter 0-5 50 0.01 ±5%F.S. < 60S > 1 years
CH4 Meter 0-100%Lel 0-100Lel 1% ±5%F.S. <50S > 5 years
F2 Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years
GeH4 Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
HCL Meter 0-20 20 0.1 ±5%F.S. < 60S > 2 years
HCL Meter 0-200 NoDate 1 ±5%F.S. < 60S > 2 years
HCL Meter 0-1000 NoDate 5 ±5%F.S. < 60S > 2 years
HCL Meter 0-3000 NoDate 6 ±5%F.S. < 60S > 2 years
HCN Meter 0-100 1000 0.1 ±5%F.S. < 20S > 2 years
HBr Meter 0-30 100 0.1 ±5%F.S. < 60S > 2 years
H2 Meter 0-1000 2000 1 ±5%F.S. <50S > 2 years
H2 Meter 0-2000 4000 3 ±5%F.S. <50S > 2 years
H2 Meter 0-5000 1% 5 ±5%F.S. < 45S > 2 years
H2S Meter 0-50 500 0.01 ±5%F.S. < 60S > 2 years
H2S Meter 0-200 500 0.25 ±5%F.S. < 60S > 2 years
H2S Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years
H2S Meter 0-2000 3000 2 ±5%F.S. < 25S > 3 years
HF Meter 0-10 20 0.1 ±5%F.S. < 60S > 2 years
NO Meter 0-25 NoDate 0.15 ±5%F.S. < 25S > 3 years
NO Meter 0-100 NoDate 0.5 ±5%F.S. < 25S > 2 years
NO2 Meter 0-20 200 0.1 ±5%F.S. < 60S > 2 years
N2H4 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years
NF3 Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years
NaH Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
O2 Meter 0-25% 30% 0.1% ±0.1% < 6S > 3years
O3 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years
O3 Meter 0-20 50 0.02 ±5%F.S. < 60S > 2 years
O3 Meter 0-100 200 0.06 ±5%F.S. < 60S > 2 years
O3 Meter 0-200 400 0.1 ±5%F.S. < 60S > 2 years
O3 Meter 0-1000 2000 0.3 ±5%F.S. < 60S > 2 years
POCL3 Meter 0-5 50 0.01 ±5%F.S. < 60S > 2 years
PCL3 Meter 0-100%lEL 100% 1% ±5%F.S. < 60S > 2 years
PH3 Meter 0-5 25 0.01 ±5%F.S < 25S > 2 years
PH3 Meter 0-500 1000 0.5 ±5%F.S < 25S > 2 years
PH3 Meter 0-1000 2000 1 ±5%F.S < 25S > 2 years
PH3 Meter 0-2000 4000 2 ±5%F.S < 25S > 2 years
SO2 Meter 0-20 100 0.1 ±5%F.S. < 25S > 2 years
SO2 Meter 0-100 500 0.5 ±5%F.S. < 25S > 2 years
SO2 Meter 0-2000 4000 1 ±5%F.S. < 25S > 2 years
SF6 Meter 0-1000 2000 1 ±5%F.S. < 60S > 2 years
SiH4 Meter 0-20 Nodate 0.1 ±5%F.S. < 60S > 2 years
SiH4 Meter 0-50 Nodate 0.2 ±5%F.S. < 60S > 2 years
THT Meter 0-100 200 1 ±5%F.S. < 60S > 2 years
TVOC(PID) Meter 0-20 50 0.2 ±5%F.S. < 20S > 5years
TVOC(PID) Meter 0-200 500 0.1 ±5%F.S. < 20S > 5 years
TVOC(PID) Meter 0-2000 5000 1 ±5%F.S. < 20S > 5 years
Humidity (CH4 Meter Without this function) 10%-95%RH, Resolution :0.1%RH,Accuracy::± 3% R.H.
Temperature(CH4 Meter Without this function) -20~80℃, Resolution : 0.1℃, Accuracy::±0.3℃
Average value 15min,1h,8h,24h
Rechargeable battery pack DC3.7V, 800mA
Size 150mmX36mmX65mm
Weight About380g
Power supply DC5V,500mA
Approvals CE