Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
FST 3561 Power Quality Analyzer
Smart measurement and analysis
For 3-phase/4-wire system
Features
Portable design and colorful touch screen
High-performance Li-battery for long time power supply
Could test 3-phase volt, null line volt, 3-phase current, null line current, etc.
Up to 50 times harmonic testing with frequency spectrum graph
Power testing: 3-phase apparent power, active power, reactive power, power factor, and 3-phase electric power.
3-phase unbalance testing with vivid chart
Record at least 40 times of surge current
Testing for wave motion, short-time flicker and long-time flicker
Record up to 40 times of sag and swell
Could have long-time record for basic (stable) power quality parameter. Recording time interval adjustable between 3 second and 30 minutes.
Digital oscilloscope, checking waveform for voltage and current signal
With FST Data View software for convenient analyzing of testing result
Technical Parameter
LCD: 5.7” 320 x 240 TFT touch screen
Input Impedance: 1MΩ,20pF
Measurement Range: Vrms 10~700V
Arms:5A, 10A, 100A, 1000A, 1500A and 3000A
(with relative current clamps)
Frequency: 40Hz~70Hz
Harmonic Measurement: 0~50th harmonics
Inrush Current: 2000A
Peak Voltage: 1000V
Internal Memory: 128MB
Communication Port: USB
N.W.(main unit): 1.6 kg (3.53lb)
Battery: durable for 5 hours after full charge
Typical Applications
Trouble-elimination: fast measurement and display on screen for trouble-shooting
Predictive maintenance: test to avoid power quality problem before malfunction happens
Service function: measurement for power quality before users lead-in
Long time analysis: recording function help find out unobvious and occasional malfunction
Load analysis: check quality of electric system before adding loads
Energy evaluation: evaluate energy consumption before installation of energy-saving facilities
Specification
Specifications Range Accuracy
Volt/Amp/Hertz Volt: 10~700V (true rms)
Amps: 0.5~3000A (true rms, with relevant current clamp) N current: 0.5~25A (true rms)
Hertz: 40~70Hz Volts: ±0.5%
Amps: ±0.5%
Hertz: ±0.01Hz
NOTE: Take frequency of Phase A as total testing frequency.
Harmonic Volts: total harmonic +1~50th
Amps: total harmonic +1~50th Volts: ±0.1(%r)
Amps: ±0.05 (A)
Power testing Active Power: 0.05~700KW
Apparent Power: 0.05~700KVA
Reactive Power: 0.05~700KVAR
Power Factor: 0.00~1.00
Active Energy: 0.01~10000kWh
Apparent Energy: 0.01~10000kVAh
Reactive Energy: 0.01~10000kVARh
Average Power Factor: 0.00~1.00 Active Power: indication±50W
Apparent Power: indication±50VA
Reactive Power: indication±50VAR
Power Factor: indication±0.05
Active Energy: indication±0.05kWh
Apparent Energy: indication±0.1 kVAh
Reactive Energy: indication±0.1 kVARh
Average Power Factor: indication±0.005
Unbalance Fundamental Volts: 10~700V (true rms)
True Amps: 0.5~1000A (True rms)
Fundamental Hertz: 40~70Hz
Phase Angle: 0~360o
Unbalance: 0.0%~100% Volts: ±0.5%
Amps: ±0.5%
Hertz: indication±0.01Hz
Phase Angle: indication±0.3 o
Volt unbalance: indication ±0.2%
NOTE: Take frequency of Phase A as total testing frequency.
Data Recording Recording for: 3 phase voltage, current, null current, voltage harmonic (THD and 1~50 harmonics), current harmonics ( THD and 1~50 harmonics), unbalance, KW, PF, flicker and fluctuation Time interval: 3s~30m adjustable
Time duration: <960 hours
Sags(Dips)/Swells Volts sag, Volts Swells and instant interruption Maximally could record 40 times
Fluctuation Voltage Fluctuation:0.1%~10.0% ≤±5%
Flicker Short-time and long-time flicker Short-time: ≤±5%
Scope
3-phase Volts, 4-wire Current, null volt and null current waveform Max Hertz: 200KHz Min Hertz: 100Hz