High Precision Three-phase Reference Standard Energy Meter ST1000

본문 바로가기


Home > Product > High Precision Three-phase Reference Standard Energy Meter ST1000
Product
High Precision Three-phase Reference Standard Energy Meter ST1000
Posting date : Oct 11, 2011
Membership
Free Member Scince Oct 11, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
Brief Introduction ST1000 high precision three-phase reference standard energy meter is developed our company. It adopts high accuracy A/D and DSP. It can be used for measurement of AC voltage, current, active power, reactive power, apparent power, power factor, phase, frequency and so on, and it can harmonic analysis, computer energy meter error. Features and Functions 1. Wide range measurement: Voltage measurement range( phase to phase) 1V~480V, current measurement range 1mA~120A; Once wiring without switch 2. Multimode measurement: AC voltage, current, active power, reactive power, apparent power and energy measurement in single/three phase Y/Δ various circuits in four quadrants. Reactive power and energy can measure true reactive power and cross phase reactive etc. 3. Multifunctional measurement: Besides the measurement of AC voltage, current, power and energy, measurement of frequency, phase, power factor, power stability, energy demand, dissymmetry of three phase system and waveform distortion etc. also can be done 4. Harmonic power measurement: analysis the active/reactive power of 2nd~50th harmonic 5. Energy error testing: Energy metrology error and estimated value of standard deviation of energy meter and energy meter test equipment can be tested 6. Data and diagram display: measurement state and various measurement data, actual voltage and current wave form, voltage and current phase vector diagram and harmonics spectrum display 7. Record and query: Real measurement condition record, query and redisplay at any time 8. Wiring: current input from 1Ma to 120A share a group of terminals. change current, no need to change the wiring Specifications Measurement Accuracy Voltage measurement: Measurement range(V) Error(Rd%) Class 0.01 30~480 ±0.01 5~30 ±0.02 1~5 ±0.1 Current measurement: Measurement range(A) Error(Rd %) 0.1~120 ±0.01 0.01~0.1 ±0.02 0.002~0.01 ±0.1 Active power/energy measurement: Voltage range(V) Current range(A) Error(Rd %) 30~480 0.1~120 ±0.01 0.01~0.1 ±0.02 0.002~0.01 ±0.1 Reactive power/energy measurement:: Voltage range(V) Current range(A) Error(Rd %) 30~480 0.1~120 ±0.02 0.01~0.1 ±0.1 0.002~0.01 ±0.2 Frequency measurement:(Current≥20mA Voltage≥30V) Measurement range(Hz) Error(Hz) 40~70 ±0.005 Phase measurement:(Current≥20mA Voltage≥30V) Measurement range(°) Error(°) 0~360 ±0.01 Magnetic induction Measurement Measurement range(mT) Error(mT) 0.001~0.25 ±10%±0.001mT Dotted Terminal pressure measurement: Measurement range(mV) Error(mV) 1~400 ±5%±1mV Voltage measurement: 1~480V Current measurement: 1mA~120A Signal frequency measurement: 40~70HZ Input pulse: max.120KHZ (TTL) Output pulse: high frequency: 100HZ (TTL) (Rated range) Low frequency: 1HZ (TTL) (Rated range) Working environment:Temperature20℃~30℃ Humidity: 60± 15% Auxiliary source: 220±15%V 50Hz Temperature coefficient:0.0005%/℃ Preheating time: 60min Power consumption: 50W Dimension:600mm(L)×420mm(W)×220mm(H); Weight: 25kg

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top