Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
2011 Portable DC Ammeters and Voltmeters,201131,201132,201133,201134,201135,201136,201137,201141,201138,201139,201140,201142,yokogawa 2011Portable Ammeters and Voltmeters.
2011 Portable DC Ammeters and Voltmeters
・Permanent moving coil type
・Magnetic circuit preventing external magnetic field effect
・Temperature compensation circuit is provided
Models 2011 are moving coil type instruments using a taut-band suspension system.
The suspension system providesexcellent reproducibility without friction, and strong resistance to shock impact.
These precision instruments combine a magnetic circuit (sandwich mechanism) that blocks the effects of external magnetic fields, and a superior temperature compensation circuit.
Features
Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
Stable performance ensures that changes over time are negligible.
Quick response and easy-to-read scale
Superior temperature compensation circuit reduces external temperature effects.
Magnetic circuit (sandwich mechanism) reduces the effects of external magnetic fields.
Specifications
Operating principle : Permanent moving coil
Class : JIS C 1102, equivalent to Class 0.5 (Notes1.)
Operating position : Horizontal
Scale length : Approximately 135 mm (deflection angle: 85°)
Scale divisions : 100/150
Operating temperature and humidity ranges : 0 to 40°C, 25 to 80%RH
Storage temperature and humidity ranges : -10 to 50°C, 25 to 80%RH
Insulation test : Between electrical circuit and the case DC 500 V/More than 10 MΩ
Voltage test : Between electrical circuit and the case AC 3000 V for 5 seconds
Scale
2011 41 50 mV instrument and 2011 42 1 mA instrument
The scale for the 50 mV instrument has 100 and 150 divisions. A 50 mV current
transformer may be combined with any rated current instrument to read
measurements through a simple conversion process. DC scales (single scale or dual
scale) are also available by special order.
Scale on 2011 41 50 mV instrument
External dimensions and weight:
2011 Approximately 197 × 181 × 92 mm, approximately 1.7 kg
2012 Approximately 260 × 180 × 120 mm, approximately 2.8 kg
Standard accessories : Instruction Manual (1)
Shunt cable (2011 41, 2012 00 only)
Optional accessories (sold separately) : 2291 01 Carrying case for 2011 (page 10)
2292 01 Carrying case for 2012 (page 10)
Model
Maximum scale value
Approximate internal resistance
and consumed power
Accuracy
DC Ammeters
2011 31
3/10/30/100 μA
5.1/18.3/7.7/2.5KΩ
±1.0%
2011 32
10/30/100/300 μA
6.8/6.8/2.5/0.88 KΩ
±1.0%
2011 33
0.1/0.3/1/3 mA
750/750/278/97.5 Ω
±0.5%
2011 34
1/3/10/30 mA
23/14/4.7/1.6 Ω
±0.5%
2011 35
10/30/100/300 mA
50mv
±0.5%
2011 36
0.1/0.3/1/3 A
50mv
±0.5%
2011 37
1/3/10/30 A
50mv
±0.5%
2011 41
50mv
500UA
±0.5%
DC Voltmeters
2011 38
0.3/1/3/10 V
1mA(1.000Ω/V)
±0.5%
2011 39
3/10/30/100 V
2011 40
30/100/300/1000V
2011 42
3V
1mA
±0.5%
Notes
1. 201131 and 201132 are equivalent to Class 1.0.
2. For ranges higher than 30 A, externally connect a shunt 2215-2217 (page 10) to the 50 mV terminal on 2011 41 (50 mV instrument) or 2012, 2011 41 (50 mV instrument) and 2012 both come with aset of shunt cables (two 1.5-meter cables with 0.025 Ω resistance). Different cables may be used if the cable resistance is 0.1 Ω or less.