TDS Water Quality Testing Pen

본문 바로가기


Home > Product > TDS Water Quality Testing Pen
Product
TDS Water Quality Testing Pen
Posting date : May 22, 2007
Membership
Free Member Scince May 14, 2007
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
Product feature 1) large four-digit LCD 2) one button operation: ergonomic and easy to use 3) auto reading hold function 4) Auto shut off function. 5) calibration function 6) super power saving 7) automatic temperature compensation(option) Operation instruction [ Measuring TDS ] 1) prepare the water sample in a container such as a paper cup 2) remove the probe cap,and press the button.the LCD will display”000” 3) dip the probe into sample.the meter body is partially water-resistant only and should stay dry 4) stir gently for 2-3 seconds.and then remove the meter from water toobtain TDS reading.the meter has an auto reading hold function to keep reading on LCD until next measurement or power is off 5) for a new measurement press button to clear reading.the LCDwill display”000” 6) after measurement,gently fling the meter 2-3 times to remove any residual water from the probe before putting the cup on.the meter automatically shuts off after approximately 30 seconds from power-on 7) to turn off the meter manually.press the button for approximately seconds. [ Installing/changing battery ] 1) remove the battery cover 2) install new 3v CR2032 battery.and make sure the dattery is properly placed with the positive”+”side up 3) close the battery compartment.then press the button to check if the LCDlights up.if the LCD dose not light up,check if the battery is good or is properly placed,and then repeat above steps 4) change battery when the LCD become dim [ Note ] 1) the meter is partially moisture-resistant only.please be careful during use and storage to avoidmaifunction or damage due to moistere 2) part of the meter such as LCD is fragile.please keep the meter from falling.being crushed or damaged 3) use a screwdriver to turn the calibration button clockwise or counterclockwise to sdjust the TDS reading.do not adjust the button unless a calibration is necessary learn more about our product website:www.moonyue.com

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top