PM-70 Patient Monitor

본문 바로가기


Home > Product > PM-70 Patient Monitor
Product
PM-70 Patient Monitor
Posting date : Jan 21, 2011
Membership
Free Member Scince Jan 20, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
84-
Package & Delivery Lead Time
Detailed Description
Feature ■ Routine Check Mode and Continuous Monitoring Mode ■ Data Graph and Trend Table Review ■ Rich Analysis Report ■ Sync with PC based Sofrware (WinXP and WinVista) ■ lightweight and easy-to-use portable unit ■ Built-in NIBP module ■ Automated & on-demand NIBP measurements ■ User or system-defined inflation pressure ■ ECG is optional NIBP: ■ Performance Specifications ■ Display:3.5" Color TFT ■ Resolution:320x240 ■ Display Mode:Standard face, Waveform face ■ Indicator:Power indicator light, Alarm sound, Pluse tone ■ Interface:socket for connecting sensors and sockets for communication cables ■ Power Supply:DC 5V, <300mA ■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours ■ for continous working.8 hours for standby mode ■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours. ■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items. ■ Alarm:Ajustable High and Low limits. Three level audible and vistual alarm ■ User Configuration:All the color of parameters and waves can be set according to user's willing Technical specifications: ■ Safety ■ Meet the requirment of IEC60601 series ■ Type of Protection:Class II with internal electirc power supply ■ Degree of Protection:BF ■ Dimention and Weight ■ Dimention:145(W)x95(H)x37(D)mm ■ Weight:400g(with battery) ■ Operation Environment: ■ Temperature:0℃~ +40℃ ■ Humidity:15% ~ 95% ■ Storage Environment: ■ Temperature:-20℃~ +60℃ ■ Humidity:10% ~ 95% ■ Patient Range ■ Neonate ,Pediatric and Adult SPO2: ■ Measurement Range:0 ~ 100% ■ Resolution:1% ■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion) ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified ■ Alarm Range:0% ~ 100% ■ Refreshing Rate:1s Pulse Rate: ■ Measurement Range:25 ~ 250 bpm ■ Resolution:1bpm ■ Accuracy:±3 bpm (non-motion) ■ Alarm Range:25 ~ 250 bmp ■ Refreshing Rate:1s NIBP: ■ Method:Oscillometry ■ Mode:Manual/Auto/Contiuous ■ Measurement Range:25 ~ 260mmHg ■ Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes ■ Resolution:1mmHg ■ Overpressure Protection: 300mmHg ■ Alarm range: 25 ~260mmHg

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top