Conventional Control Panel

본문 바로가기


Home > Product > Conventional Control Panel
Product
Conventional Control Panel
Posting date : Aug 07, 2008
Membership
Free Member Scince Aug 07, 2008
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
Features 1) 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs). - All zones accept two-wire smoke detectors and any normally-open contact devices. - Zones 1 4/8/16 configured as general alarm zones. 2) All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology. 3) Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs). 4) NACs may be programmed: - Silenceable - Non-Silenceable - Auto-Silence (program 5 to 20 minutes) 5) 1.25 amps of NAC power 6) 3.0 amps of total system power 7) Alarm, Trouble and Supervisory, Form-C relays standard. 8) 24-volt operation 9) Resettable four-wire smoke detector power @ 500 mA 10) Non-resettable power @ 500 mA 11) Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent). 12) One-man walk-test programmable for silent or audible test 13) Disable/Enable control per IDC 14) Reverse polarity protection 15) Control buttons: - Mode - Test - ACK (Acknowledge) Alarm Silence - Reset 16) Meet UL864, EN-54 standard. 17) LED indicators: - AC Power (green & yellow LED) - Fire Alarm (red LED) - Trouble (yellow LED) - Supervisory (yellow LED) - Signal Silence (yellow LED) - Battery Power (green & yellow LED) - Zone Disable (yellow LED) - NAC Fault (yellow LED) - NAC Disable (yellow LED) - 4/8/16 Zone Alarm (one for each zone) (red LED) - 4/8/16 Zone Trouble (one for each zone) (yellow LED) - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger Fault (on circuit board) Specifications AC Power: AC220V±10% 50Hz, 2.0 amps, minimum 14 AWG wire (2.0 mm²) with 600-volt insulation. Battery: Sealed lead-acid batteries only, Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge, Maximum battery charger capacity: 18AH battery NOTE: two 4AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total 24 V system power: 3.0 amps Notification appliance (signal) power: 2.5 amps Maximum current per NAC: 1.25 amps (expandable to 2.5 amps) Auxiliary Outputs: - Resettable four-wire smoke detector power @ 500 mA - Non-resettable power @ 500 mA - Integral Form-C Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive). NOTE: Total current for auxiliary power outputs and two NACs must not exceed 3.0 amps. Dimensions: 320×260×80mm (length × width × depth) Using Environment: Temperature: 10°C~+50°C Related Humidity: ≤95% (40±2°C)

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top