Data Center data center hardware

본문 바로가기


Home > Product > Data Center data center hardware
Product
Data Center data center hardware
Posting date : Mar 15, 2021
Membership
Free Member Scince Mar 15, 2021
FOB Price
-
Min. Order Quantity
It depends on the specific product
Supply Abillity
It depends on the specific product
Port
Chengdu
Payment Terms
L/C90 or T/T90
Package
It depends on the specific product
Keyword :
Category
Contact
Han Lee
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Jiancheng
HS-CODE
8471-
Package & Delivery Lead Time
Package
It depends on the specific product
Delivery Lead Time
45Days
Detailed Description

Data Center    data center hardware    internet data center   idc micro module    Data Center manufacturer

 

windstream data center Description  

The Airtight Channel System

The Characteristics of System

Channel system controls the air transport path, provides high density of refrigeration guarantee;

Significantly improve the cool air utilization of the air-conditioning system, reduce consumption of data room;

Cold Aisle is modular design so that can achieve quick connect;

Intelligent control host can connect with fire extinguishing system,and upload the data of environment;

Using the design of fire-proof material automatic monitoring and warning improve security.

 

The Frame of Cool Channel Airtight System

By obturating cool air entrance in the front of cabinet, the cool channel airtight system can put the cool air made by precision air-conditioning transport to the front-end of IT device as design plan. In order to improve the utilization of heat and cool air and realize the effect of energy saving and emission reduction by adding a flow sealing plate to isolate heat and cool air inside of the cabinet. The structure include channel activity containment door, channel airflow containment door, airflow control units of floor and cabinet.

 

The Frame of Heat Channel Airtight System

The heat channel airtight system, by concentrating heat air in the control areas exhausted behind the cabinet, and unify reflow to precision air-conditioning return air grille so that heat air can not spread in internal cabinet during the whole process. The cold source air inlet of the cabinet is not disturbed by it, and there is no energy loss of the product, which improves the efficiency of air conditioner.

 

Jiancheng-Data Center Rack Design Structure Characteristics

Meet the standards of ANSI/EIA-310-D, GB/T15295-94, GB/T3047.2-92, IEC61587-2-2011; Compatible standard of ETSI;

The frame of whole cabinet made by sheet metal; static load1300kg; dynamic load 1000kg;

Complete machine delivery, or spare parts delivery; easily assemble and reduce transportation and storage space;

The width of the cabinet is standard 600mm and 800mm; depth and height can be arbitrary configuration;

The front door can configure hexagonal wire mesh door whose ventilation rate can achieve 75%, or can configure glass door; both of them compatible the opening methods of left way and right way so that convenient to adjust the direct of opening based on site needs of customers;

The back door can configure double mesh door to save the space.of cabinet installation;

Side plate use double open of up and down so that convenient disassembly and installation;

Each parts of the cabinet inside can be grounded;

Installation vertical post print the installation indicate position so that the user can install convenient;

The cabinet configure the universal wheels and stand bar so that it can be moved and fixed convenient;

Flexible cabinet pick the mountings; up cabling and down cabing is compatible.

 

Material/Superficial Treatment

Electrostatic spraying.

 

600, 800 Arc Mesh Cabinet

Width of 600 and 800 combination cabinet, the front door's material is mesh ventilation material, depth between 600 to 1200 can be configured, height between 24U to 47U can be configured, the color have computer gray and black.

The way of exhausting air: enter from front and exit from back.

 

600, 800 glass cabinet

Width of 600 and 800 combination cabinet, the front door’s material is glass, depth between 600 to 1200 can be configured, height between 24U to 47U can be configured, the color is computer gray and black.

The way of exhausting air: enter from bottom and exit from back.

 

600, 800 Plate Mesh Cabinet

Width of 600 and 800 combination cabinet, the front door's material is plate mesh, depth between 600 to 1200 can be configured, height between 24U to 47U can be configured, the color is gray and black.

The way of exhausting air: enter from front and exit from back.

 

Our data center hardware is data center rack layout for windstream, We can customize IDC micro module according to customer needs and provide refrigeration guarantee.

 

UPS power supply, several kinds of ups electrical system are sold. We provide UPS power supply program support. Jiancheng is also a charging pile supplier about integrating technology, after-sales, installation and maintenance.

 

https://www.jch-electronics.com/product-data-center-hardware.html

 


ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top