Three-zone thermal shock equipment
Using low temperature and high temperature storage cool and heat tank, according to the cylinder valve action needs, high temperature energy and low temperature energy to the test tank, so as to achieve rapid temperature impact effect. Balanced temperature regulation control system (BTC) + specially designed air supply circulation system control SSR by PID mode, so that the heat added to the system, is equal to the amount of heat loss, so it can be used for a long time and stably.
Shocking temperature is -40c to 150c.
Model | TSD-50F-3P | TSD-80F-3P | TSD-100F-3P | TSD-150F-3P | TSD-252F-3P | TSD-480F-3P | ||||||
Litre | 49L | 80L | 100L | 150L | 252L | 480L | ||||||
Test basket size(cm) | 35x40x35(W*D*H) | 50x40x40(W*D*H) | 50x40x50(W*D*H) | 60x50x50(W*D*H) | 70x60x60(W*D*H) | 80x60x85(W*D*H) | ||||||
External chamber size(cm) | 132x190x181(W*D*H) | 139x148x180(W*D*H) | 154x1480x185(W*D*H) | 164x168x195(W*D*H) | 174x180x205(W*D*H) | 184x210x218(W*H*D) | ||||||
High temperature zone | +60℃~+180℃ | |||||||||||
Heat up time | +60℃~+180℃≦25min (Performance in high temperature zone individual working.) | |||||||||||
Low temperature zone | -60℃~+10℃ | |||||||||||
Cooling time | +20℃~-60℃≦60min (Performance in low temperature zone individual working.) | |||||||||||
Shocking temperature | (+60℃~+150℃) to (-40℃~ -10℃) | |||||||||||
Performance | Fluctuation | ±0.5℃ | ||||||||||
Deviation | ±2.0℃ | |||||||||||
Recover time | ≦5min | |||||||||||
Handover time | ≦10sec | |||||||||||
Noise | ≦65db | |||||||||||
Loading | 1kg | 2kg | 3kg | 5kg | 8kg | 10kg | ||||||
Material | External material | Anti-rust treatment of cold rolled steel plate + 2688 powder coating/SUS#304 steel stainless. | ||||||||||
Internal material | Steel stainless (SUS304, 2B polishing processing). | |||||||||||
Insulating material | Enclosure by rigid polyurethane foam, door by glass wool. | |||||||||||
Refrigeration system | Refrigerating method | Mechanical bipolar compression refrigeration. (Air cooled condenser/Water cooled heat ex-changer.) | ||||||||||
Compressor | Totally enclosed Tecumseh France compressor and semi-hermetic Bitzer Germany for optional. | |||||||||||
Compressor refrigerating capacity | 3.0HP*2 | 4.0HP*2 | 4.0HP*2 | 6.0HP*2 | 7.0HP*2 | 10.0HP*2
|