Model | SUNDI-655WV | SUNDI-675WV | SUNDI-6A10WV | SUNDI-6A15WV | SUNDI-6A25WV | |
Temp. range | -60℃~+300℃ (system add pressure 3BAR) | |||||
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | |||||
Temp. control | Process temp control and jacket temp control model | |||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | |||||
Program Editor | 10 programs, each program can edit 42 steps. | |||||
Communication Portocol | MODBUS RTU Protocol, RS485 interface | |||||
Material temp. feedback | PT100 OR 4~20mA or communication(normal: PT100) | |||||
Temp. feedback | The temp of three points: the inlet and outlet of equipment, reactor material temp(external temp sensor) | |||||
Medium temp. acccuracy | ±0.5℃ | |||||
Material temp. accuracy | ±1℃ | |||||
Heating power kW | 5.5 | 7.5 | 10 | 15 | 25 | |
Cooling capacity kW at | 300℃ | 5.5 | 7.5 | 10 | 15 | 25 |
100℃ | 5.5 | 7.5 | 10 | 15 | 25 | |
20℃ | 5.5 | 7.5 | 10 | 15 | 25 | |
-20℃ | 4.8 | 6 | 8.2 | 12 | 25 | |
-40℃ | 2.3 | 3.1 | 4.8 | 7.8 | 18 | |
-55℃ | 0.75 | 0.9 | 1.5 | 2.8 | 6 | |
Circulation pump maxL/min bar | 50 | 50 | 110 | 110 | 150 | |
2 | 2 | 2.5 | 2.5 | 2.5 | ||
Pump | LNEYA magnetic drive pump | |||||
Compressor | Tecumseh closed compressor | Dorin semi-closed compressor | ||||
Expansion valve | Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve. | |||||
Evaporator | DANFOSS/KAORI Plate heat exchanger | |||||
Operation Panel | 7-inch touch screen,show temp curve\EXCEL data output | |||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | |||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | |||||
Refrigerant | R404A/R23 mixture,optional: R125/R23 mixture | |||||
Connection size | G3/4 | G1 | G1 | G1 | DN32 PN10 | |
Water-cooled type W(cooling water@20℃) | 1800L/H1.5bar~4bar | 2100L/H1.5bar~4bar | 3000L/H1.5bar~4bar | 4000L/H1.5bar~4bar | 8.5m³/H1.5bar~4bar | |
Dimension cm | 55*95*170 | 55*95*170 | 70*100*175 | 80*120*185 | 100*150*185 | |
Weight kg | 265 | 305 | 340 | 380 | 980 | |
Power 380V 50HZ | 10kW | 14kW | 18kW | 26kW | 40kW |
Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.