Quick Detail
Place of Origin
Brand Name
Hexcell
Model Number
LXSIC-15/20/25
HS-CODE
85-
Package & Delivery Lead Time
Package
Normal Packing or As Customers' Request
Delivery Lead Time
Shipped in 30 days after payment
Detailed Description
Electrical Smart Water Meter RS485 , 1/2" to 1 Water Meter With Remote Reader
Key Features
ISO 4064 Class B* Made of PPO or brass
LCD and Dry-Dial display
Horizontal installation
Advantage
Made of PPO which is up to the mustard of drinking water .
Due to easily being operated by touch less card, this meter is all-sealed and good at water proof.
Safely data save, 10 years data save after power off .
Periodic open/close valve to prevent valve from rust buildup .
Battery can be used for 6 years due to low consumption design .
Automatic close valve when being effected by strong magnet .
Batter is easy to be replaced .
Patented ball valve which has high-temperature resistance, costs low consumption and causes lowpressure loss .
One or Several Mifare card prepaid meter for one family,one card for several meters si avaliable,
including cold,hot and purified water meter,electricity meter and gas meter .
Meter function
Prepaid water meter, one meter accepts one user card only, blocking illegal cards .
One price/ multi price of water is available .
Inquiring, statistics, Refund, Re-issuing card, replacing meter .
Low credit alarm, Low battery alarm .
Parameters
Maximum permissible error:
1. 5% error limit from minimum flow rate (q min) to transitional flow rate (qt) (included)
2. 2% error limit from transitional flow rate (qt) to overload flow rate (q Max)
- - - -
Caliber(DN) | 15mm | 20mm | 25mm | 40mm |
Measure Unit | 0.1m |
Measurement Range Ratio(Q3/Q1) | 63/80/100 |
Overflow Flowrate(Q4) | 3.125m/h | 5m/h | 7.875m/h | 20m/h |
Common Flowrate(Q3) | 2.5 m/h | 4 m/h | 6.3 m/h | 16 m/h |
Demarcation Flowrate(Q2) | 0.05m/h | 0.08m/h | 0.126m/h | 0.32m/h |
Minimum Flowrate(Q1) | 0.0313m/h | 0.05m/h | 0.0788m/h | 0.2m/h |
Q2/Q1 | 1.6 |
Q4/Q3 | 1.25 |
Minimum Reading | 0.0001 m |
Maximum Reading | 99999 m |
Working Temperature | 0.1~30(Cold Water Meter) |
0.1~90(Hot Water Meter) |
- - - -
Installation size
- - - -
Caliber | D1 | D2 | H |
DN(mm) | mm |
15 | 190 | 94 | 113 |
20 | 195 | 94 | 113 |