Quick Detail
Place of Origin
Brand Name
Mitech
Model Number
MHBS-3000Z
HS-CODE
85-
Package & Delivery Lead Time
Package
carton box
Delivery Lead Time
8-10 days after paid
Detailed Description
MITECH MHBS-3000Z Touch Screen Automatic Tower Digital Display Brinell Hardness Tester
Overview
Mitech MHBS-3000Z Touch Screen Automatic Tower Digital Display Brinell Hardness Tester, based on the mechanical principle of hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the diameter of the indentation, The use of photoelectric sensor system to high magnification optical measurement, equipped with automatic turret device, high sensitivity touch screen operation interface, can achieve automatic loading and unloading of electronic, easy to operate, high detection efficiency. It can meet the hardness testing requirement for the quality control and qualified assessment of the workpiece sample. It is widely used in metal processing and manufacturing, various metal materials failure analysis and other fields like colleges and research institutions. Its to improve the work efficiency, product qualification rate, saving production costs necessary professional precision testing equipment.
Technical Parameters
- - - -
Technical specifications | Technical Parameters |
The power series | 612.5N(62.5kgf),980N(100kgf),1225N(125kgf),1837.5N(187.5kgf), 2450N(250kgf),4900N(500kgf),7350N(750kgf),9800N(1000kgf),14700N(1500kgf),29400N(3000kgf) |
Measuring range | 8 650 HBW |
Conversion scale | HRA,HRB,HRC,HRD,HV,HK,HBW,HR15N,HR30N,HR45N,HR15T,HR30T,HR45T |
Brinell scale | HBW2.5/62.5,HBW2.5/187.5,HBW5/125,HBW5/250, HBW5/750,HBW10/100,HBW10/1500,HBW10/3000, HBW10/250,HBW10/500, HBW10/1000 |
Testing Force Application Mode | Automatic (loading, holding, unloading) |
Indenter objective lens conversion mode | Automatic |
[display usage] | LCD touch screen |
Microocular magnification | 20X |
Test force holding time | 0~60s |
Minimum division | 0.001 mm |
Max sample height | 230mm |
Max distance from head to body | 140mm |
Voltage | AC 220V/50Hz |
Size | 620*270*900mm |
Total Weight | 130kg |
- - - -
Indication accuracy
- - - -
Standard Block | Indicating Error%(H) | Repeatability Error |
125 | 3 | 0.03`d |
125HBW225 | 2.5 | 0.025`d |
225 | 2 | 0.02`d |
- - - -
H:Hardness of standard block `d: Indentation diameter(average)
Working Principle
Hardness is not a simple physical quantity, but a reflection of the material elasticity, plasticity, strength and toughness .and hardness test is the most simple mechanical testing method to determine the metal material performance. Also one of the important means to judge the products quality.
Brinell hardness test: Test force(F) is on the steel ball with certain diameter(D) , pressed on sample surface. After a period of time, cancel the force. The indentation diameter is get by measuring with micrometer ocular,thus to calculate the average pressure(N/mm).Then we can get the Brinell hardness of the sample as below:
Tips:FTest force on steel ball,unit:N
DDiameter of steel ball ,unit:mm
dIndentation diameter,unit:mm
0.102Rule coefficient
Features
# Suitable for measuring the surface is more rough cast iron, steel and other non-homogeneous specimen Brinell hardness;
# The use of automatic closed-loop pressure sensor control system, can dynamically reflect the loading process load changes.
# The automatic turret mechanism can realize the automatic switching function between the objective lens and the indenter and improve the detection efficiency.
# Using touch screen display interface, display operation integration, simple and intuitive, the technical requirements of the operator is not high;
# Modeling novel, strong structure, reliability and operability is high, intuitive, high test efficiency;
# Equipped with excellent performance of the carbide indenter, high hardness, wear resistance, good toughness, while high temperature, corrosion resistance, to ensure that the instrument measured standard, stable and reliable;
# Support Brinell, Rockwell, Vickers and other hardness standard conversion;
# Equipped with high-speed thermal printer, you can quickly print out the test data;
# Meet ISO6507, ISO6506, GB / T231, JJG150 and other relevant domestic and foreign standards..
Applied condition
# Cast iron, steel, non-ferrous metals, soft alloy of metal material
# Hard plastic, bakelite and some nonmetallic material.
Application field
# Metal processing industry quality control links
# Universities teaching and demonstration test
# The failure test of metal material
# The material hardness test of scientific research institutions
Working conditions
# Working Temperature:1828
# Relative Humidity:65
# Clean environment, no vibration
# No corrosive media around.
Configuration
- - - -
Standard Configuration | No. | Item | Quantity | Note |
1 | Main body | 1 | |
2 | 20Lens | 1 | |
3 | 2.5mm ball | 1 | |
4 | 5mm ball | 1 | |
5 | 10mm ball | 1 | |
6 | Small testing table | | Diameter 80mm |
7 | Large testing table | 1 | Diameter 200mm |
8 | V-shape testing table | 1 | For cylindrical sample |
9 | Standard Hardness Block HBW/3000/10(150-250) | 1 | |
10 | Standard Hardness Block HBW/1000/10(75125) | 1 | |
11 | Standard Hardness Block HBW/187.5/2.5(150-250) | 1 | |
12 | Fuse wire(2A) | 3 | |
13 | RS232 Cable | 1 | |
13 | Power line | 1 | |
14 | Plastic dust cover | 1 | |
15 | Attached files | 1 | |
16 | Instrument case | 1 | |
Optional Configuration | 1 | Brinell measurement system | | |
- - - -
Maintenance and care
# Each technical requirement of the instrument has already reached the national standards before leaving factory. But its disassembly, transportation or voltage after delivery might cause some data in the instrument changed. So to make the electronic component in normal operation to reduce the testing error, you can use test force of 29400N(3000kgf) pressing times before starting the instrument to eliminate the instrument deformation.
# The anti-interference component has been installed in the circuit to ensure the transmission of the loading or unloading single of the test force at all levels. At the same time, make sure no strong interference source around when using the instrument, and power off the instrument after finished the testing.
# All the screws and the caps have been fasten tightly before the instrument leaving factory. However, the screw and cap may become less crowded because that the screw lever for loading and unloading are rotating all the time. If there is irregular noise, when the screw lever rotating, please check and tightened the screw and cap as the below figure shown.
Pulley and cap
# If there is some tiny noise when unloading, it is normal and no need to worry.
# Hardness of the use of a period of one year, two adjacent indentation or indentation center to the edge of the distance of not less than 3mm, too close will affect the measured results;
# The instrument screw level and other movable surface should be lubricated regular
# When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the hardness block, indenter should be coated with antirust oil to prevent rusting after using.
# Start using again after long time idling, please make testing after preheating the electrical components.
# The accuracy of the reading microscope has been adjusted before leaving factory. It is prohibited to disassembly without authorization. Otherwise, it will reduce the reading accuracy of the micro eyepiece.
# The storage and using of the reading microscope should avoid dust, damp and corrosive gas environment;
# If there is dirt on the surface of the reading microscope lens, please wipe it with soft absorbent cotton or lens paper. If there is oil pollution, please wipe it slightly by the absorbent cotton with industrial alcohol or ether.
# Dont disassemble the instrument without authorization, maintenance related matter, please contact MITECH after-sale service department with 4000600280.