Mitech MHR-150A High accuracy Durable High quality and inexpensive Manual Rockwell Hardness Tester

본문 바로가기


Home > Product > Mitech MHR-150A High accuracy Durable High quality and inexpensive Manual Rockwell Hardness Tester
Product
Mitech MHR-150A High accuracy Durable High quality and inexpensive Man...
Posting date : Jun 01, 2018
Membership
Free Member Scince Apr 23, 2018
Port
Beijing,China
Payment Terms
T/T, Wester
Package
carton box
Keyword :
Category
Contact
Lareina Lee
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Mitech
Model Number
MHR-150A
HS-CODE
85-
Package & Delivery Lead Time
Package
carton box
Delivery Lead Time
8-10 days after paid
Detailed Description
Mitech MHR-150A Manual Rockwell Hardness Tester Overview Mitech MHR-150A Manual Rockwell Hardness Tester, based on the mechanical principle of conical diamond or hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation. Capable of inspecting the finished or semi-finished parts of the machined sample, it is suitable for high accuracy hardness testing for batches parts with various metal or non-metallic materials. According to statistics, Rockwell hardness testing is the most widely used hardness testing method in metal processing industry, which utilization ratio is more than 70%. With novel appearance, stable performance and convenient visual reading of the classical dial, It is widely used in metal processing and manufacturing, various metal materials failure analysis and other fields like colleges and research institutions. It is the new type Brinell hardness testing instrument for testing the hardness of the materials like cast iron, steel, soft alloy and so on. Technical Parameters - - - - Technical specifications | Technical Parameters | Preliminary Testing force | 98.07N,tolerance 2.0% | Testing force | 588.4N, 980.7N, 1471N , tolerance 1.0% | Hardness Measuring range | HRA:20-88,HRB:20-100,HRC:20-70,HRD:40-77,HRE:70-100, HRF:60-100,HRG:30-94,HRH:80-100,HRK:40-100 | Testing Force Application Mode | Manual operation | Indenter specification | Diamond cone Rockwell indenter,1.5875mm steel ball indenter | Display | Mechanical dial | Indication error | 0.1HR | Indicator scale | 0~100(C),30~130(B) | Rockwell scale | HRA,HRB,HRC,HRD,HRE,HRF,HRG,HRH,HRK | Maximum height of specimen | 170mm | Distance of Indenter to outer wall | 135mm | Dimension | 510212700mm | Main unit weight | 85kg | - - - - Indication error - - - - Scale | Standard Hardness Range | Allowed Maximum Tolerance | HRA | 20-75HRA | 2HRA | 75-88HRA | 1.5HRA | HRB | 20-45HRB | 4HRB | 45-80HRB | 3HRB | 80-100HRB | 2HRB | HRC | 20-70HRC | 1.5HRC | HRD | 40-70HRD | 2HRD | 70-77HRD | 1.5HRD | HRE | 70-90HRE | 2.5HRE | 90-100HRE | 2HRE | HRF | 60-90HRF | 3HRF | 90-100HRF | 2HRF | HRG | 30-50HRG | 6HRG | 50-75HRG | 4.5HRG | 75-94HRG | 3HRG | HRH | 80-100HRH | 2HRH | HRK | 40-60HRK | 4HRK | 60-80HRK | 3HRK | 80-100HRK | 2HRK | HRL | 100-120HRL | 1.2HRL | HRM | 85-110HRM | 1.5HRM | HRR | 114-125HRR | 1.2HRR | - - - - Working Principle The Rockwell hardness test is taking the diamond cone with 120apex angle or the hardened steel ball with specified diameter as the indenter to press into sample surface with specific test force, then get the Rockwell hardness of the measured metallic materials according to the sample surface indentation depth. The Rockwell hardness measurement principle is shown as below figure. 0-0 is the position that the diamond indenter is not yet in contact with the sample. 1-1 figure is the indenter position under the affect of the [preliminary] test force, the indentation depth is h1. The [preliminary] test is to eliminate the influence to the testing result accuracy caused by the roughness of the sample surface. 2-2 in the figure is the indenter position under the influence of the testing force (the preliminary test force and the main test force). The depth is h2. 3-3 in the figure is the indenter position after dismounting the main test force. As the metal elasticity will recovery some degree after deformation, the really indentation depth of the indenter is h3. The plastic deformation caused by the main test force make the indenter pressing into the depth is hh3h1. Rockwell hardness value is determined by the size of h, the greater the depth h, the lower the hardness, otherwise, the higher the hardness. In the traditional concept, usually use a constant C minus h to represent the level of hardness, while the depth of indentation per 0.002mm as a unit of hardness. The hardness value obtained is called the Rockwell hardness value, denoted by the symbol HR. In the formula, c is a constant (for HRC, HRA, c is 0.2; for HRB, c is 0.26). The Rockwell hardness value HR obtained is an unknown number which is usually read directly on the test machine indicator when testing. Rockwell hardness tester working principle Figure It should be noted that the measured hardness values would be different with different indenter and test force. Therefore, the Rockwell hardness testing specifies 15 different hardness test scales according to the different indenter specification and test force sizes. And the HRB, HRC, HRA are the most widely used. Features # Widely used for high-precision hardness testing for parts with a variety of metal and non-metallic materials, # Using the classic design of mechanical and manual device, data reading intuitive and convenient, without external power supply, performance stable and reliable; # Option for various specifications of the indenter, support 15 types of Rockwell hardness scales testing. # With diamond indenter, durable and wear-resistance, the measurement is accurate. accurate measurement; # Consistent with GB/T230.1, GB/T230.2, JJG112, GB/T230.2, ISO 6508-2, ASTM, E18 and other related domestic and foreign standards. Scale - - - - Scale | Indenter type | [preliminary] testing force (N) | Testing force (N) | Measuring Range | Application | A | Diamond cone | 98.07(N) | 588.4(N) | 20-88HRA | hard alloy, carbide, surface quenched steel, carburizing steel | D | 980.7(N) | 40-77HRD | thin steel sheet, surface quenched steel | C | 1471(N) | 20-70HRC | quenched steel, tempered steel, chilled cast iron | F | 1.5875 1/16 inch steel ball | 588.4(N) | 60-100HRF | cast iron, aluminum, magnesium alloy, bearing alloy | B | 980.7(N) | 20-100HRB | mild steel, copper alloy, annealed steel | G | 1471(N) | 30-94HRG | phosphorus iron, beryllium bronze, malleable cast iron | H | 3.175 1/8inch steel ball | 588.4(N) | 80-100HRH | aluminum, zinc, lead etc. | E | 980.7(N) | 70-100HRE | bearing alloy, tin, hard plastics and other soft materials | K | 1471(N) | 40-100HRK | L | 6.35 1/4 inch steel ball | 588.4(N) | 50-115HRL | Hard plastic ,hard rubber, aluminum, tin, bronze, mild steel, synthetic resin, friction materials and etc. | M | 980.7(N) | 50-115HRL | R | 12.7 1/2 inch steel ball | 588.4(N) | 50-115HRL | - - - - Applications # Used for quality control in metal processing manufacturing # Used for failure analysis testing of metallic materials; # Demonstration experiment for education and teaching in Colleges and Universities; # Hardness testing of materials in scientific research institutions Working Conditions # Operation Temperature:1030 # Relative Humidity:65 # The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configurations - - - - | NO. | Name | QTY. | Remarks | Standard Configuration | 1 | Main unit | 1 | | 2 | Diamond Rockwell indenter | 1 | | 3 | 1.5875mm 1/16in steel ball indenter | 1 | | 4 | Counterweights | 3 | | 5 | Small Testing Table | 1 | Dia 60mm | 6 | Large Testing Table | 1 | Dia 150mm | 7 | V-shape Testing Table | 1 | Test cylindrical specimens | 8 | Rockwell Standard Block HRB | 1 | | 9 | Rockwell Standard Block HRC | 2 | High value and low value | 10 | Big screw driver | 1 | | 11 | Small screw driver | 1 | | 12 | Plastic Dust Cover | 1 | | 13 | Attached files | 1 | | 14 | ABS instrument case | 1 | | Optional Configuration | 1 | 3.175mm 1/8inch steel ball indenter | 1 | Mainly use to testing Rockwell hardness for non-ferrous materials like hard plastic and so on. | 2 | 6.35mm 1/4inch steel ball indenter | 1 | 3 | 12.7mm 1/2inch steel steel ball indenter | 1 | - - - - Maintenance and care # During testing, to ensure accuracy, please make sure the distance between the adjacent indentation center and the distance from the indentation center to edge of the specimen is greater than 3mm. # Normally, the first point is only used to offset the gap of each support surface without needing to record the test result. Record the statistical test result from the second point. # Screw protective cover is designed to protect the screw from dust invasion. When instrument idle or test specimen height less than 100 mm, it should be set on the outside of the screw. For testing the specimen with height above 100mm, it should be taken out for normal use. # It is strictly prohibited to turn the variable loading handwheel when the instrument load or unload the test force. Rotating the handwheel forcibly will cause the internal gear dislocation, test force in chaos and even damage the internal parts of the instrument # If the specimen has visible deformation marks on the back and edges, the test result would be useless. It should choose the intender or test force to test again. # The test personnel shall strictly observe the operating procedures. Please use the standard blocks often to calibrate the instrument before and after testing. # Pay attention to palm the instrument for carrying to forbid falling across. Please fix well the measuring lever, counterweight and boom before carrying. # When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the hardness block, indenter should be coated with antirust oil to prevent rusting after using. # Please regularly put a small amount of oil on the screw and the handwheel interface # The hardness tester should be calibrated at least once a year to ensure its accuracy # Dont disassemble the instrument without authorization, for maintenance related matters, please contact MITECH after-sale service department with 4000600280

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top