Quick Detail
Place of Origin
Brand Name
Fanhar
Model Number
W15-1
HS-CODE
85-
Package & Delivery Lead Time
Package
export carton,33*22*16(cm)/50pcs
Delivery Lead Time
10- 15 days
Detailed Description
16A 250VAC PCB Mounting Industrial Relay Coil Power 0.25W DC12V
In some applications, it is necessary to select a magnet-held relay in order to conserve power when the relay contact is switched on for a long time, and it is often used for short-time driving, so that the relay is held and not driven. In addition, in some stable environments (the temperature does not change, the vibration is not the basic), In addition, in some stable environment (temperature change is not, the impact of vibration is basically no), in order to save electricity, it is often to use maintain pressure. In this case, the magnitude of the buck is generally not less than 50% of the rated voltage. (Such as power monitoring circuit, alarm circuit.)
Basic Info:
Model NO.: W15-1
Contact Form: 1A = 1 OPEN 1B= CLOSE 1C= 1 Switch
Product protective: S=Sealed Nil= Soldered
Contact material: AgSnO2
Coil Power: Nil= Standard L = Sensitive
Insulation System:Nil:B grade F= F grade
Dimension: 29*12.7*15.7 mm
Weight: Approx 12g
Trademark: FANHAR
Origin: China
Product Description:
1. 16A contact switching capability
2. Normally open type has the UL certification of TV-8 125VAC,
the impact current is 120A
3. The withstand voltage between coil and contact can reach 12KV.
4. Creepage distance and spacial distance are greater than 15mm.
5. UL insulation class : F grade.
Contact Data:
- - - -
Contact Form | 1A 1B 1C |
Rated load | 16A 250VAC/30VDC
12A 250VAC/30VDC |
Max Switching Voltage | 277VAC/30VDC |
Max Switching Current | 16A |
Max Switching Capacity | 4000VA/480W |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 100m (at 6VDC 1A) |
Insulation Resistance | 1000M (at 500VDC) |
- - - -
General Data:
- - - -
Withstand Voltage Between open contacts | 1000VAC 1min |
Between coil and contacts | 4000VAC 1min |
Operate Time | Max.15ms |
Release Time | Max.5ms |
Mechanical life | 10,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 16A 250VAC/30VDC 100,000 ops ON/OFF=1s/9s
12A 250VAC/30VDC 100,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation
Durability | 100m/s Approx10G
1000m/s Approx100G |
Vibration Resistance Misoperation
Durability | 10 - 55 Hz 1.5mm Double Amplitude
10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40C to +85C |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Certification | UL/C-UL:E475405
TUV:R50332875
CQC:CQC15002137649 |
- - - -
Coil Data:
Standard:
- - - -
Coil rated voltage | Operating
voltage | Releasing
Voltage | Coil rated
Current
(10%) | Coil resistance(10%) | Rated consumed power | Allowing voltage |
DC 3V | Below 75%
rated voltage (initial) | above 5%
rated voltage (initial) | 133mA | 22.5 | 400mW | 90-130 %
Rated voltage |
DC 5V | 80mA | 62.6 |
DC 6V | 66.7mA | 90 |
DC 9V | 44.5mA | 202.5 |
DC 12V | 33.4mA | 360 |
DC 15V | 26.7mA | 562.5 |
DC 18V | 22.3mA | 810 |
DC 24V | 16.7mA | 1440 |
DC 48V | | | 8.4mA | 5760 | | |
- - - -
Sensitive:
- - - -
Coil rated voltage | Operating
voltage | Releasing
Voltage | Coil rated
Current
(10%) | Coil resistance(10%) | Rated consumed power | Allowing voltage |
DC 3V | Below 75%
rated voltage (initial) | above 5%
rated voltage (initial) | 83mA | 36 | 250mW | 90-130 %
Rated voltage |
DC 5V | 50mA | 100 |
DC 6V | 41.7mA | 144 |
DC 9V | 27.8mA | 324 |
DC 12V | 20.9mA | 576 |
DC 15V | 16.7mA | 900 |
DC 18V | 13.9mA | 1296 |
DC 24V | 10.5mA | 2304 |
DC 48V | | | 5.3mA | 9216 | | |
- - - -