Quick Detail
Place of Origin
Brand Name
Fanhar
Model Number
W39
HS-CODE
85-
Package & Delivery Lead Time
Package
export carton, 24*24*35(cm) per 75pcs
Delivery Lead Time
10-15 days
Detailed Description
Miniature PCB Power Relay With Ambient Temperature -40 - 85
The majority of the failure of the relay in the application is caused by the load. Due to the actual parameters of the load or application circuit is not fully confirmed, it results in the use of relays with no match, and resulting in the relay contact adhesion, contact wear and tear depletion, contact instability, control circuit occurs to short circuit, performance deterioration of relay insulation, and more severe cases may cause like security risks. Therefore, it is very important to use the relay correctly and safely.
Basic Info
# # Model NO.: W39
# Contact Form: 1A= 1OPEN 1C = 1 Transformation
# PCB Mounting: 1 = type 1 2= type 2
# Product protective: S=Sealed Nil= Soldered
# Contact material: T = AgSnO2
# Coil Power: Nil = 530mW L= 360mW
# Insulation level: B: B level F: F level
# Dimension: 29*12.7*25 mm
# Weight: Approx 15g
# Trademark: FANHAR
# Origin: China
Product Description
1. 16A contact switching capability
2. Normally open type has the UL certification of TV-8 125VAC, the impact current is 120A
3. The withstand voltage between coil and contact can reach 10KV
4. Optional socket installation
Contact Data:
- - - -
Contact Form | 1A 1C |
Rated load | 16A 250VAC/30VDC
12A 250VAC/30VDC |
Max Switching Voltage | 277VAC/ 30VDC |
Max Switching Current | 16A |
Max Switching Capacity | 4000VA/480W |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 100m (at 6VDC 1A) |
Insulation Resistance | 1000M (at 500VDC) |
- - - -
General Data:
- - - -
Withstand Voltage Between open contacts | 1000VAC 1min |
Between coil and contacts | 4000VAC 1min |
Operate Time | Max.15ms |
Release Time | Max.5ms |
Mechanical life | 10,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 16A 250VAC /30VDC 100,000 ops ON/OFF=1s/9s
12A 250VAC /30VDC 100,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation
Durability | 100m/s Approx10G
1000m/s Approx100G |
Vibration Resistance Misoperation
Durability | 10 - 55 Hz 1.5mm Double Amplitude
10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40C to +70C |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Certification | TUV UL CQC ISO ROHS |
- - - -
Coil Data:
Standard:
- - - -
Coil rated voltage | Operating
voltage | Releasing
Voltage | Coil rated
Current
(10%) | Coil resistance(10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75%
rated voltage (initial) | above 5%
rated voltage (initial) | 106mA | 47 | 530mW | 90-130 %
Rated voltage |
DC 6V | 58.8mA | 153 |
DC 12V | 44.2mA | 272 |
DC 24V | 22.1mA | 1087 |
DC 48V | 11.5mA | 4170 | | |
DC 100V | 5.3mA | 18860 | | |
- - - -
Sensitive:
- - - -
Coil rated voltage | Operating
voltage | Releasing
Voltage | Coil rated
Current
(10%) | Coil resistance(10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75%
rated voltage (initial) | above 5%
rated voltage (initial) | 71.4mA | 70 | 360mW | 90-130 %
Rated voltage |
DC 6V | 60mA | 100 |
DC 12V | 30mA | 400 |
DC 24V | 15mA | 1600 |
DC 48V | 7.5mA | 6400 | | |
- - - -