Moisture (Water Content)
|
≤ 3 ~ 5 PPM
|
Gas Content
|
≤0.01% (Vol)
|
Impurities Degree (Filtration precision)
|
≤ 1 micron (no free carbon)
|
Breakdown Voltage (Dielectric)
|
≥73 KV
|
Flash Point
|
≥145℃
|
Cleanliness
|
≤NAS 1638 Grade 6
|
Parameters
|
Model
Unit
|
ZYD-L-50
|
ZYD-L-100
|
ZYD-L-150
|
ZYD-L-200
|
ZYD-L-250
|
ZYD-L-300
|
Flow Rate
|
L/H
|
3000
|
6000
|
9000
|
12000
|
15000
|
18000
|
Working Vacuum Degree
|
MPa
|
-0.08 ~ -0.099
|
|||||
Working
Discharge Pressure
|
MPa
|
≤ 0.3
|
|||||
Temperature
Control Range
|
℃
|
20 ~ 80
|
|||||
Operation Temperature
|
℃
|
40 ~ 70 (65℃ is best)
|
|||||
Power Supply
|
|
380V, 50Hz, 3 phases (or as per your requirements)
|
|||||
Working hours
without Trouble
|
Hour
|
4000
|
|||||
Continuous Working Hours
|
Hour
|
150
|
|||||
Ambient Temperature
|
|
-25 ~ 55℃
|
|||||
Working Noise
|
dB(A)
|
65 ~ 90
|
|||||
Heating Power
(adjusted available)
|
KW
|
36
|
48
|
60
|
72
|
80
|
120
|
Total Power
|
KW
|
42
|
52.5
|
68
|
82
|
93
|
135
|
Inlet/Outlet
|
mm
|
φ32
|
φ42
|
φ50
|
φ50
|
φ60
|
φ60
|
Gross Weight (KGS)
|
Machine Part
|
830
|
1190
|
1350
|
1490
|
1600
|
1950
|
Trailer Parts
|
430
|
500
|
570
|
640
|
700
|
800
|
|
Dimension
L×W×H (mm)
|
Machine Part
|
1710
×1350
×2150
|
1900
×1420
×2190
|
1940
×1480
×2220
|
2120
×1500
×2240
|
2150
×1700
×2350
|
2300
×1850
×2460
|
Trailer Parts
|
2760
×1860
×1050
|
2900
×1900
×1060
|
3010
×1920
×1060
|
3020
×1940
×1070
|
3050
×1980
×1090
|
3090
×2000
×1120
|