Detailed Description
NITI MTF Engine, ,root canal instruments, ISO, used for dental
Specifications:
- - - -
Taper | V0 | .05 |
V1 | .03 |
V2 | .04 |
T1 | .07 |
T2 | .08 |
T3 | .09 |
T4 | .06 |
T5 | .05 |
Torque | V0 | 3.0 N/CM |
V1 | 3.0 N/CM |
V2 | 1.0 N/CM |
T1 | 1.5 N/CM |
T2 | 2.0 N/CM |
T3 | 2.0 N/CM |
T4 | 2.0 N/CM |
T5 | 2.0 N/CM |
Rotary Speed Range | V0 | 325-375 RMP |
V1 | 325-375 RMP |
V2 | 325-375 RMP |
T1 | 325-375 RMP |
T2 | 325-375 RMP |
T3 | 325-375 RMP |
T4 | 325-375 RMP |
T5 | 325-375 RMP |
Size | V0 | #19 |
V1 | #18 |
V2 | #20 |
T1 | #20 |
T2 | #25 |
T3 | #30 |
T4 | #40 |
T5 | #50 |
ISO Color | V0 | Yellow |
V1 | Violent |
V2 | White |
T1 | Yellow |
T2 | Red |
T3 | Blue |
T4 | Yellow |
T5 | Red |
Using Times | V0 | 8-10 times |
V1 | 10-12 times |
V2 | 10-12 times |
T1 | 8-10 times |
T2 | 12-15 times |
T3 | 12-15 times |
T4 | 12-15 times |
T5 | 12-15 times |
Cross Section | Triangle |
- - - -
Description:
NITI MTF is the multiple tapered instrument. With exclusive multiple taper design which is different from normal Endo Files. MTF make canal shaping easier, safer, faster, and more efficient.
Structure
1. Shaping Files(V0,V1,V2):Using V0 to make the formation of crown and short root canal, preparation the upper 1/3 root canal with V1, V2 for middle 1/3 root canal preparation.
2. Finishing FilesT1,T2,T3:All used for the formation of 1/3 root canal tip.
Operation Sequence:
1. Establishing linear channel , cleaning the canal with sodium hypochlorite
2. Detect the root canal Using #10, #15 SSK file
3. Makes the formation of crown with V0 and create the canal path (cleaning with Sodium Hypochlorite )
4. Preparation the upper 1/3 crown with V1 , flush canal with sodium hypochlorite solution (STDN ) after getting it out
5. Using the same rotary method to the working length with V2 , and flush canal with sodium hypochlorite solution (STDN )
6. Using T1 to the working length , which could make a smooth connect between the 1/3 canal tip and middle 1/3 canal
7. T2 to the working length and using #25 K files to measure the diameter of apical foramina , which indicating finished the preparation and it could be filled if it is loose
8. Using the T3 to the working length if you didn't feel loose when using the #25 K files.
Warning:
1.Only skilled dentists are allowed to use.
2. Be sure to sterilize this product for each use.
3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use.
1. To prevent infection, sterilize the product by autoclave and make sure
sterilization is completed before using.
2. Choose the most appropriate type for each case and follow the general
method.
3. Before using, make sure the instruments outside of dental cavity that
there are no deformations, scratches and cracks.
4. If the head of product is thin, long or large, there are possibilities for
breaking or twisting. Because of this, be sure to avoid using
unreasonable angle and excessive pressure.
5. Wear safety glasses to protect your eyes from damage. Also, wear a
dust protective mask to prevent inhaling dust.
6. Wear rubber dam etc. to avoid accidental ingestion and falling.
7. Do not use this instrument for any purposes except for listed
applications above.
8. Only for use by dentists.
9. After using, follow an appropriate treatment as medical waste.
10. Dispose the product if damaged or contaminated.
11. After using, wash it with medical cleaning agent and brush, then
wash away foreign substances like adherent body fluids and body
tissues.
12. Set the product to a stand when cleaned by ultrasonic cleaner to avoid
working part deterioration.
13. Use this product with great care to avoid puncturing fingers because
of its possession of sharp-edged part.
1. Avoid storing at high temperature, humidity and direct sunlight.
Keep liquids away. Store it at room temperature.
2. Do not damage or make a pinhole to packaging materials.
3. Do not keep under germicidal lamp to avoid deterioration.
1. Sterilize this product by autoclave under established method and
term for each use.
Method of sterilization:
Put this product in a sterilization pack or (or foil) and place it on a
sterilization tray, or files stand for autoclave sterilization with
reference to the following terms.
Terms for sterilization:
term(1) temperature: 121degrees Celsius time: 20 minutes or more
term(2) temperature: 126degrees Celsius time: 15 minutes or more
2. Do not use high pressure steam sterilizer which heats more than 200
degrees Celsius including drying process.
3. When reusing the instrument, wash away foreign substances
completely and sterilize.
4. Regarding use of medical cleaning agent, follow the instruction
manual by its manufacturer strictly.
5. Dispose the product if damaged or decreased in performance
Packages
1. Minimum packaging unit: 6 pcs. /package (V0,V1,V2,T1,T2,T3,T4,T5)
2. Assortment: 1 pc. from each size/package (V0-T3)
Legal Manufacturer
SHENZHEN PERFECT MEDICAL INSTRUMENTS CO., LTD
Add:1F, Bldg. C Plant, No.3, Jixia Zaohekeng Industrial Area, Nanwan St., Longgang Dist., Shenzhen, China, 518000
Tel:+86-755-28540953 Fax:+86-755-28540953
EU Representative
Well Kang Limited
The Black Church, St.Mary's Place, Dublin 7, Ireland
Applications:
- - - -
Dental Root Canal Treatment | Hospital , Clinic , lab... |
- - - -
Competitive Advantage:
Root canal preparation is one of the most important factor in RCT. Flexibility and shape memory of NiTi instrument, to improve preparation efficiency and reduce fatigue.
To know NiTi feature and cross section design well ,which can get a better understanding about instrument performance and do the best choice.