MG3, NITI M-Wire Gold taper File, root canal Instruments , ISO, used for dental

본문 바로가기


Home > Product > MG3, NITI M-Wire Gold taper File, root canal Instruments , ISO, used for dental
Product
MG3, NITI M-Wire Gold taper File, root canal Instruments , ISO, used f...
Posting date : Mar 23, 2018
Membership
Free Member Scince Feb 05, 2018
FOB Price
negotiatable
Port
China
Payment Terms
T/T, Wester
Package
6 pcs/packing , single & assorted ,packed in box t
Keyword :
Category
Contact
Oscar
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
D-Perfect
Model Number
Starter G1 G2 G3 P1 P2
HS-CODE
85-
Package & Delivery Lead Time
Package
6 pcs/packing , single & assorted ,packed in box t
Delivery Lead Time
10-15 working days after received the payment
Detailed Description
MG3, NITI M-Wire Gold taper File, root canal Instruments , ISO, used for dental Specifications: - - - - Taper | Starter | 1.2 | P1 | .02 | P2 | .02 | G1 | .04 | G2 | .06 | G3 | .04 | Torque | Starter | 3.0 N/CM | P1 | 2.0 N/CM | P2 | 2.0 N/CM | G1 | 2.0 N/CM | G2 | 2.0 N/CM | G3 | 2.0 N/CM | Rotary Speed Range | Starter | 350 RMP | P1 | 300 RMP | P2 | 300 RMP | G1 | 300 RMP | G2 | 300 RMP | G3 | 300 RMP | Size | Starter | #120 | P1 | #16 | P2 | #19 | G1 | #20 | G2 | #25 | G3 | #35 | ISO Color | Starter | Yellow | P1 | White | P2 | Yellow | G1 | Yellow | G2 | Red | G3 | Green | Using Times | Generally difficult root canals | 10-15 times | Moderately difficult root canals | 8-10 times | Difficult root canals | 1-2 times | Cross Section | Triangle | - - - - Description: For simple root canal: Operation Sequence: 1. 1. Use 10 # or 15 # stainless steel hand use files to search and check root canals 2. Use starter file to open the crown and upper-middle of the root canal 3. Use 10 # or 15 # stainless steel hand use K files to search and check root canals until the WL 4. Use G1,G2 to search until the WL 5. Use G3 to repeat cutting until the WL for curved root canal 6. Using sodium hypochlorite solution for fully flush when every file preparation is finished and use 10# or 15# K file to cut until the WL. For complex root canal: Operation Sequence : Use K file (stainless steel) to search, prepare to extend the upper-middle of root canal according to personal habits, or use #10 or #15 files in order to operate. 2. Use starter file to prepare the upper-middle of root canal and build a straight path to reach at middle-lower of root canal; Use 10# or 15# stainless steel K file to search the middle-lower of root canal to confirm the working length, then use P1(02/16#),P2(02/19#) to smooth the root canal until the working length 3. Use the series of G files Successively to prepare the root canal to the working length:G1(04/20#),G2(06/25#),G3(04/35#) Operation Method To adjust rotary speed and torque, turn on motor and use MG3 files to achieve the working length, then replace files in order after 2-3 times up-and-down pulling. Remark:Most of the root canals are usually completed preparing with G2. But if non-enough preparation after G2, be continued with G3. Warning: 1.Only skilled dentists are allowed to use. 2. Be sure to sterilize this product for each use. 3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use. 1. To prevent infection, sterilize the product by autoclave and make sure sterilization is completed before using. 2. Choose the most appropriate type for each case and follow the general method. 3. Before using, make sure the instruments outside of dental cavity that there are no deformations, scratches and cracks. 4. If the head of product is thin, long or large, there are possibilities for breaking or twisting. Because of this, be sure to avoid using unreasonable angle and excessive pressure. 5. Wear safety glasses to protect your eyes from damage. Also, wear a dust protective mask to prevent inhaling dust. 6. Wear rubber dam etc. to avoid accidental ingestion and falling. 7. Do not use this instrument for any purposes except for listed applications above. 8. Only for use by dentists. 9. After using, follow an appropriate treatment as medical waste. 10. Dispose the product if damaged or contaminated. 11. After using, wash it with medical cleaning agent and brush, then wash away foreign substances like adherent body fluids and body tissues. 12. Set the product to a stand when cleaned by ultrasonic cleaner to avoid working part deterioration. 13. Use this product with great care to avoid puncturing fingers because of its possession of sharp-edged part. 1. Avoid storing at high temperature, humidity and direct sunlight. Keep liquids away. Store it at room temperature. 2. Do not damage or make a pinhole to packaging materials. 3. Do not keep under germicidal lamp to avoid deterioration. 1. Sterilize this product by autoclave under established method and term for each use. Method of sterilization: Put this product in a sterilization pack or (or foil) and place it on a sterilization tray, or files stand for autoclave sterilization with reference to the following terms. Terms for sterilization: term(1) temperature: 121degrees Celsius time: 20 minutes or more term(2) temperature: 126degrees Celsius time: 15 minutes or more 2. Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying process. 3. When reusing the instrument, wash away foreign substances completely and sterilize. 4. Regarding use of medical cleaning agent, follow the instruction manual by its manufacturer strictly. 5. Dispose the product if damaged or decreased in performance Packages 1. Minimum packaging unit: 6 pcs. /package (Starter G1 G2 G3 P1 P2) 2. Assortment: 1 pc. from each size/package (Starter G1 G2 G3 P1 P2) Legal Manufacturer SHENZHEN PERFECT MEDICAL INSTRUMENTS CO., LTD Add:1F, Bldg. C Plant, No.3, Jixia Zaohekeng Industrial Area, Nanwan St., Longgang Dist., Shenzhen, China, 518000 Tel:+86-755-28540953 Fax:+86-755-28540953 EU Representative Well Kang Limited The Black Church, St.Mary's Place, Dublin 7, Ireland Applications: - - - - Dental Root Canal Treatment | Hospital , Clinic , lab... | - - - - Competitive Advantage: MG-3 is consisted of starter,G1,G2,G3,P1,P2 while G1/G2/G3 these three files are the working files with simple, efficient and safe operation. 1. Simple :For most of the root canals just need 2 working system files. It is usually completed preparing with G2.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top