Automated Portable Multi Parameter Patient Monitor / All In One Vital Sign Machine

본문 바로가기


Home > Product > Automated Portable Multi Parameter Patient Monitor / All In One Vital Sign Machine
Product
Automated Portable Multi Parameter Patient Monitor / All In One Vital ...
Posting date : Jan 24, 2018
Membership
Free Member Scince Jan 16, 2018
FOB Price
competitive
Port
CHINA
Payment Terms
L/C, T/T, ,
Package
carton, wooden case
Keyword :
Category
Contact
Cathy Wu
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
STATEMED
Model Number
STT-601D
HS-CODE
85-
Package & Delivery Lead Time
Package
carton, wooden case
Delivery Lead Time
10 working days
Detailed Description
Quality Guaranteed Medical Portable Multi-parameter Patient Monitor Power - - - - Supply power | AC 110/230V10% 50/60Hz2% | power | 50VA | Fuse specifications and models, rating | T2.0AL/250V F520 | Display mode | LCD display | Alarm mode | Audible and visual | Network connection | Can be expanded | - - - - Battery - - - - Battery type | Lithium battery 11.1V/4.4Ah | Recharge time | 4hours | Use time | 3hours | - - - - Work Environment - - - - Environment temperature | Working 5+40 Transportation and storage -40+55 | Relative humidity | Working 85% Transportation and storag 95% | Atmospheric pressure | Working 700hpa1060hpa Transportation and storag 500hpa1060hpa | - - - - ECG - - - - Sensitivity | 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,40mm/mV,erro3% | Scan speed | 12.5,25,50mm/s three level,erro 10% | Adjustable screen aspect ratio | 0.053.2 | Lead off condition detected | U=2V I=0.04uA | Active noise suppression | In patients who have not applied current | Tall T-wave suppression | 1.4mV | Inner voice | <30VP-P | Input impedance | 2.5M | Input loop current | 0.1A | endure electrode polarizing voltage | 300mV | ECG signal input range | 5mV | Measurement mode | Diagnosis mode,monitoring mode,operation mode | Frequency property | Diagnosis mode 0.05130HZ monitoring mode 0.540HZ operating 120HZ | CMRR | Diagnosis mode 80dB Monitoring mode 90dB Operating mode 100dB | HR measurement range | Adult 30250bpm Neonate /pediatrics 30300bpm | HR accuracy | 2% | HR sensitivity | >200V | Heart rate calculation | Take 4 to 12 R-wave cycle averaged | Refresh time heart rate | 1S | Heart rate response time | 80-120 BPM:range 4-7s Average 4-7s 80-40 BPM: range 4-7s Average 4-7s | Alarm range | 0301bpm,upper and lower limit can be adjusted continuously | Alarm indicator | Audial and visual alarm | Heart rate too fast startup time of the alarm | Range :4-6s Average :4-6S | Protection | Isolated immunity voltage 4000V,50/60HZImmunity of electronic surgical Anti-defibrillation | Protection and recovery for defibrillation effect | In the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S. | Electrode polarization recovery time after the fibrillation | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | Surgical interference of electrical recovery time | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | - - - - Sp02 - - - - SpO2 measurement range precision | 0100% 2%(70100% ) | PR measurement range precision | 20300 bpm 2% | Alarm range | 0100%,upper and lower limit can be adjusted continuously | Alarm indicator | Audial and visual alarm | - - - - RESP - - - - Measurement range | Adult 7120 bpm Pediatric /neonate 7150 bpm | Precision | 2bpm | Impedance test range | 0.33 | Base line impedance range | 2004000(50120kHz pump-frequency) | Apnea alarm time | 1040s | Alarm range | 0121bpm,up and down limit can be adjusted continuously | Alarm indicator | Audial and visual alarm | Test waveform | F=63kHz Vp-p=6V I=250uA | - - - -

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top