MPPT solar energy system charge controller with 99% MPPT tracking efficiency
PC1600F Series
MPPT Solar Charge Controller
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.
Feature:
l 45A/60A/80A MPPT solar charge controller(Fan cooling) 12V/24V/48V auto work
l MPPT efficiency>99%,Peak conversion efficiency >98%
l DSP processors technology ensure high speed and performance
l Multi-stage charging mode Protection: PV array short circuit ,
l PV reverse polarity , Battery reverse polarity , Over charging , Output short circuit
MODEL | PC16-4515F | PC16-6015F | PC16-8015F | |
Nominal Battery System Voltage | 12V/24V/36V/48VDC (Auto detection) | |||
CONTROLLER INPUT |
PV Open Circuit Voltage | 100VDC@12V/ 145VDC @24V/ 145VDC @36V/ 145VDC @48V | ||
PV Array MPPT Voltage Range |
16VDC~100VDC / 32VDC~130VDC / 48VDC~130VDC / 64VDC~130VDC |
|||
Max PV Input Power(12V) | 600W | 800W | 1050W | |
Max PV Input Power(24V) | 1200W | 1600W | 2100W | |
Max PV Input Power(36V) | 1800W | 2400W | 3150W | |
Max PV Input Power(48V) | 2400W | 3200W | 4200W | |
BATTERY | Absorption Voltage | 12.5VDC/25.0VDC/37.5VDC/50.0VDC | ||
Refloat Voltage | 13.7VDC/27.4VDC/41.1VDC/54.8VDC | |||
Float Voltage | 14.3VDC/28.6VDC/42.9VDC/57.2VDC | |||
Low Voltage Protection Point | 8.5VDC/17VDC/25.5VDC/34.0VDC | |||
Temperature Compensation coefficient | -3mv/°C /cell (25°C vef) | |||
PATTERY | Peak Conversion efficiency | 98% (MPPT Efficiency 99%) | ||
Max Charging Current |
45 amps continuous @ 40°C ambient |
60 amps continuous @ 40°C ambient |
80 amps continuous @ 40°C ambient |
|
GENERAL SPECIFICATION |
Radiating mode | Fan cooling | ||
DISPLAY& PROTECTION | LED indication |
Systematic operation, LV indication, LV protection, over charge protection, short circuit protection |
||
LCD display |
Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current |
|||
Alarm Protections | PV array short circuit, PV reverse polarity | |||
Battery reverse polarity, Over charging protection | ||||
Output short circuit protection | ||||
Low voltage protection for storage battery | ||||
MECHANICAL SPEC. |
Mounting | Wall mount | ||
Machine Dimension(W*H* D) | 167.6*257.2*82.9mm (per pcs) | |||
G.W(Kg) | 3Kg/pcs | |||
Package Dimension(W*H* D) | 612*308.2*235.6mm (5pcs/Carton) | |||
Gross Weight(Kg) | 17.4Kg(per Carton) | 19Kg(per Carton) | ||
OTHER | Environmental Rating | Indoor | ||
Operation Temperature Range | -25~55°C | |||
Ambient humidity | 0~90% relative humidity(non-condensing) | |||
Altitude | ≤3000m | |||
Loading(20GP/40GP/40HQ) | 3000pcs / 6000pcs / 7200pcs |