Professional 200A Telecom Rectifier System , Telecom Rectifier Module System DC48V

본문 바로가기


Home > Product > Professional 200A Telecom Rectifier System , Telecom Rectifier Module System DC48V
Product
Professional 200A Telecom Rectifier System , Telecom Rectifier Module ...
Posting date : Nov 09, 2017
Membership
Free Member Scince Oct 26, 2017
FOB Price
negotiation
Port
Shenzhen, China (Mainland)
Payment Terms
L/C, D/A, D
Package
carton/wooden case
Keyword :
Category
Contact
Fiona Liang
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
ESTEL
Model Number
GPE48200N
HS-CODE
85-
Package & Delivery Lead Time
Package
carton/wooden case
Delivery Lead Time
7-10 working days
Detailed Description
Professional 200A Telecom Rectifier System , Telecom Rectifier Module System DC48V Quick Details: - - - - Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V/AC110V | Brand Name: ESTEL | Output Voltage: DC48V | Model Number: GPE48200N | Output Power:10700W/5350W | Product Name: Telecom Rectifier System | Input Frequency: 45~65Hz | Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 67A | Installation Mode: 19 rack | Power Factor: 0.98 | Application: outdoor telecom cabinet | Components: 450A rectifier module, 1monitoring module, 1PDU. | - - - - Payment & Shipping Terms: - - - - Minimum Order Quantity: | 1 set | Price: | negotiation | Payment Terms: | L/C, D/A, D/P, , T/T, Western Union | Supply Ability: | 20,000 sets per month | Delivery Time: | 7-10 working days | Packaging Details: | carton/wooden case | - - - - 1.Specifications Technical Parameters - - - - Input | Item | Min. | Typical | Max. | Unit | Remark | Input Voltage Range | 90 | 220 | 290 | Vac | | Input Frequency | 45 | 50 | 65 | Hz | | Max. Input Current | | | 67 | A | | Power Factor | 0.98 | | | | Rated load | Input Over-Voltage Protection Point | 300 | | | Vac | Automatic recovery | Input Over-voltage Recovery Point | 290 | | | Vac | Backlash is not less than 5V | Input Undervoltage Protection Point | | | 85 | Vac | Automatic recovery | Input Undervoltage Recovery Point | | | 90 | Vac | Backlash is not less than 5V | Input Overcurrent Protection | | | | | AC input has air switch for protection. | Output | Item | Min. | Typical | Max. | Unit | Remark | Output Voltage | 42 | 53.5 | 58 | Vdc | Adjustable by monitoring, no-load test | Output Power | | 10700 | | W | 176 ~ 290VAC input, 10700W output (rated power, including battery charging power and load power.) | | 5350 | | W | 90 ~ 175VAC input | Environment | Item | Min. | Typical | Max. | Unit | Remark | Operating Temperature | -25 | | 55 | C | 55C, the power need to lower the power output. | Storage Temperature | -40 | | 80 | C | | Humidity | 10 | | 90 | % | Relative humidity, non-condensing. | Atmospheric Pressure | 70 | | 106 | KPa | | Altitude | 0 | | 3000 | m | | Cooling | Forced cooling fan | - - - - 2. Description GPE48200N consists of power distribution, rectifier module (min 1 module, max 4 modules), and 1 monitoring module. Please refer to the following table: - - - - Configuration | Rectifier Module | Monitoring Module | Power Distribution | Remark | Standard Configuration | GPR4850D-R01 | GPM48P-A (with Ethernet interface) | AC power distribution: single-phase input, AC mains MCB (63A/2P); (three phase input optional, modification would reduce 4 output MCBs) DC power distribution: Battery MCB 100A *2; LVD1: 100A*1, 32A*2, 63 A*2, 16 A*4 (MCB capacity optional) LVD2: 16 A*2, 32 A*2 (MCB capacity optional) | For more tech info, please read specifications. | - - - - 3. Application (1) Small scale program controlled exchangers (3) Access network (4) Transmission equipment (5) Mobile communication (6) Satellite communication ground station (7) Microwave communication 4. Features (1) Adoption of active power factor compensation technology with factor 0.98 (2) Wide operating range of AC input voltage: 90290Vac (3) Operating temperature range: -25C+55C (4) Zero current/voltage switching tech with high efficiency 91% (5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc (6) Hot-swappable (7) Input over/under voltage protection (8) Output over voltage protection (9) Output over current protection (10) Output short circuit protection (11) Auto current sharing, parallel output (12) Embedded mounting (13) Multiple communication ports, easy for networking and remote management 5. Front Power Distribution Of Telecom Rectifier System GPE48200N 6. Front Power Distribution Of Telecom Rectifier System GPE48200N 7. Packing and Shipping Our Delivery Agent The goods can be shipped by sea, by air, by courier, by land, by train, etc. Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you. 8. Our Contact Information Mobile Phone: 0086-13752765943 Telephone: 0086-0755 66600941 Email: info@estel.com.cn lxf.estel@hotmail.com Skype: fiona.liang10

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top