Customized Walk-In Chamber Environmental Chamber With Mechanically Cooled

본문 바로가기


Home > Product > Customized Walk-In Chamber Environmental Chamber With Mechanically Cooled
Product
Customized Walk-In Chamber Environmental Chamber With Mechanically Coo...
Posting date : Oct 10, 2017
Membership
Free Member Scince Sep 11, 2017
FOB Price
negotiation
Port
China
Payment Terms
T/T /C,D/A,
Package
Packed in carton firstly,and then reinforced with
Keyword :
Category
Contact
Louis Long
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
KOMEG
Model Number
KMH-6000S
HS-CODE
85-
Package & Delivery Lead Time
Package
Packed in carton firstly,and then reinforced with
Delivery Lead Time
42 working days after received your payment
Detailed Description
China Customized Mechanically cooled Walk-In Environmental Test Chambers for Accelerated Ageing Test 1. Walk-In Climate Test Chambers KOMEG Environmental test chambers offering a large volume of test space to conduct temperature and humidity testing for large batches of products or large product,such as prototype evaluation, research & development testing, production testing, accelerated stress testing, reliability testing, failure analysis, and any other application where environmental simulation is needed. KOMEG manufactures both panel walk-in chambers and solid walk-in chambers and can be configured as temperature chamber or temperature humidity chamber. 2.Main Technical Parameters - - - - .Main Technical Index | 1. Body | 1.1 Workplace volume | IW 1500 IH 2000 ID 2000 mm about 6 m | 1.2 External dimensions | IW 3050 IH 2410 ID 2200 mm | 2. Temperature | 2.1 Temp. range | -65~120 | 2.2 Temp. deviation | 2.0 | 2.4 Temp. fluctuation | 0.5 | 2.5 Temp. uniformity | 2.0 | 2.5 Heating and cooling rate | -65 +120 temperature change rate non-linear 2/min (no load) +120 -65 temperature change rate non-linear 1/min(no load) | Water-cooled. The above specifications measurement in the environment temperature at + 25 without load | 3. Humidity | 3.1 Humidity range | 20%R.H98%R.H | 3.3 Humidity deviation | 3.0RH(75RH) 5.0RH(75RH) | 3.4 Humidity fluctuation | 3.0RH (no-load) | 3.5 Humidity uniformity | 2.0RH | Water-cooled. The above specifications measurement in the environment temperature at + 25 without load | - - - - 3.Application Applicable to environmental adaptability and reliability test in such industrial units as electronics, electrical appliance, battery, plastics, food, paper product, vehicle, metal, chemistry, building material, research institution, inspection and quarantine bureau, university etc.. 4. Description Flexibility for structure The panels used in our chamber are 4 (100mm or 150mm) Thick urethane-foam sandwiched between a stainless-steel interior wall and a coated-steel exterior. An assembled box is self-supporting. So that no heavy structural members are required. Different door sizes, flooring upgrades,access ports, and other modifications are possible. Widest test range, most customizable 5. Meet the standard GB-2423. 1-89(IEC68-2-1)Test A: Low Temperature Test GB-2423. 2-89(IEC68-2-2)Test B: High Temperature Test GJB360. 8-87(MIL-STD. 202F) High Temperature Life Test GBJl50. 3(MIL-STD-810D) High Temperature Test GJBl50. 4(MIL-STD-810D) Low Temperature Test GB2423. 3-93(IEC68-2-3)Test Ca: Constant Heat Test GB2423. 4-93(IEC68-230)Test Db: Damp Heat Alternative Test GJBl50. 9-93(MIL-STD-810D) Damp Heat Test 6. Optional accessories Cable Port: Two size of cable port is available: 50mm, 100mm, 120mm Double door Pass room: Provided to avoid disturbance of atmospheric temperature and humidity while opening the door. Floor reinforcement: Can be fixed if heavy specimen placed in the chamber for test. Carry-in inclined platform: Provided below the door to facilitate moving of specimens in and out through the door. Entire ceiling blow-out duct The extremely wide air inlet reduces the airflow rate (down to apprrox.0.5m/s) Dehumidifier The rotation regenerating dehumidifier (M-300)ensures precise control of low humidity (21,23%RH)for electrostatic reliability tests. Temperature and humidity recorder 100mm width recording paper with 6 dots 180mm width recording paper with 12 dots Status indication lamp Provide to signal chamber status and warnings when normal running, a malfunction running or stand by occurs. Water purifier Provided to keep the humidifier heater free from scale and ensure the supply of water to humidifier. Power socket Air cooled or water cooled type condenser Parts brands: After-sale Service: If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer. [Specification for Walk In Climatic Test Chamber KMHW-6000S-01.pdf]

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top