11 KV - 3150kVA Dry Type Transformer Low Noise Dry Type Cast Resin Transformer

본문 바로가기


Home > Product > 11 KV - 3150kVA Dry Type Transformer Low Noise Dry Type Cast Resin Transformer
Product
11 KV - 3150kVA Dry Type Transformer Low Noise Dry Type Cast Resin Tra...
Posting date : Sep 04, 2017
Membership
Free Member Scince Aug 23, 2017
FOB Price
USD/RMB
Port
China
Payment Terms
T/T, L/C
Package
Seaworthy wooden packing
Keyword :
Category
Contact
Jenny Tan
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Pearl Electric Co.,Ltd.
Model Number
PEC-S, SC(B) 9-15
HS-CODE
85-
Package & Delivery Lead Time
Package
Seaworthy wooden packing
Delivery Lead Time
36days-50days ex-work
Detailed Description
11 kV - 3150kVA , Cast Resin Dry Type Transformer , Three Phases , Two Winding , Power Distribution Advantages: Cast resin dry typetransformer,eco-friendly, high efficiency. # # Low loss, low noise, low partial discharge, high reliability. Fitfor general users , such as hospital, tower, hotel, etc. # Strong capability withanti-short circuit, high anti-lightning impulse capability. # HV coil is vacuum casted with epoxy resin with pressure, capabilities for better the cast without pressure. Subject to customer need, both HV and LV coil are fully vacuumed. # Simulating analysis being used in the core model, the resonance can be avoided and the noise is reduced. Simulation calculation and analysis of lighting impulse wave are applied to the HV Coils; anti-lighting impulse capability is improved. -----WHY CHOOSE US ` low noise, low loss and low partial discharge. `Guarantee/warranty Quality assurance18 months after delivery or 12 months after site operation, which comes earlier. `High reputation Wide exportation fromSouth Africa to South Asia, stable supply to Malaysia, Myanmar, Italy ..etc country ,with qualified certificateauthorized by KEMA, CESI, CTQC. `Small order is also accepted 1 unit of transformer with minimum rated capacity of 100kVA. `Experienced staff Pearl Electric is national high-tech enterprise andowns more than 65expects and R&D engineers, over 2/3 of them have more than 3 years experience in technology and product developing. With such an pioneer army, Pearl devoted heart and soul on client's need to come up with perfect electriciy solution. Cast resin dry type transformer Care shall be taken to ensure that fittings are located so as not to interfere with the external connection to the bushing terminals, and the clearances to such connections shall not be less than the appropriate minimum phase-to-earth clearance given in column 2 of Table 2. The lines of approach of these connections may lie anywhere within the limits indicated in Figure 1, and the required phase-to- earth clearance shall apply at all points along these lines, as shown at the points marked 'L'. In addition, the minimum vertical working clearances from floor level to live metal shall be as listed in column 3 of Table Table 2 Electrical clearances in air - - - - System highest voltage Um (kV) | Minimum phase-to-earth clearance 'L' (see note 1) (mm) | Minimum vertical working clearance from ground level to live metal (see note 2) ( mm) | 'X'-Dimension (2,5 x L) (*Min 3 000 mm) (mm) | 'Y'-Dimension (L + 3000) (mm) | 3,6 | 80 | 2 580 | 3 000 | 3 080 | 7,2 | 150 | 2 650 | 3 000 | 3 150 | 12 | 200 | 2 700 | 3 000 | 3 200 | 17,5 | 230 | 2 730 | 3 000 | 3 230 | 24 | 320 | 2 820 | 3000 | 3 320 | 36 | 430 | 2 930 | 3 000 | 3 430 | 48 | 540 | 3 040 | 3 000 | 3 540 | 72 | 770 | 3 270 | 3000 | 3 770 | 100 | 840 | 3 340 | 3 000 | 3 840 | 145 | 1 200 | 3 700 | 3 000 | 4 200 | 1) Dimension not applicable to standard bushings per se | 2) The minimum distance from the transformer base or ground level to the flange base of a bushing (or surge arrester) shall be 2 500 mm. | - - - - - - - - No. | Items | Unit | PEC-S-kVA/HV/LV | I Basic Information | | | 1 | Rated Voltage ratio | kV | 11kV / 0.433 kV | 1.01 | Rated Capacity | kVA | 3150 | II Electric Performance | | | 2.01 | Rated Power | kVA | 3150 | 2.02 | HV | kV | 11 | 2.03 | LV | kV | 0.433 | 2.04 | Frequency | Hz | 50 | 2.05 | Number of phase | | Three | 2.06 | Insullation Class | | Class H | 2.07 | Temperature Rise (@40 ambient temperature) | K | 125K | 2.08 | Cooling Method | | AN | 2.09 | Tapping Ranging | | 2*2.5% | 2.1 | Vector Group | | Dyn11 | 2.11 | Noise level | dB | 61 | 2.12 | Impedance | % | 7 | 2.13 | No-load loss | W | 4500 | 2.14 | Load Loss (@120) | W | 23500 | 2.15 | Local Partial discharge | pC | <10PC | 2.16 | Impulse Withstand Voltage (HV/LV) | kV | 75/0 | 2.17 | Power Frequency Withstand Voltage (HV/LV) | kV | 28/3 | 2.18 | Rated Duration of Short Circuit | s | 2 | - - - - 2 Applied Standard GB/T10228 , GB1094.11 , IEC60076-11 , DIN42523

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top