Introduction
The Rosemount 8800D Vortex MultiVariable Vortex Flow Meter option combines temperature and flow devices into a single, highly accurate instrument, eliminating the costly installation of two separate devices. The integrated, removable temperature sensor is isolated from the process and separate from the Vortex flow sensor. This facilitates independent verification or replacement of each sensor without shutdown or breaking the process seal. Additionally, the MultiVariable Vortex automatically adjusts for changes in density, making it easy to accurately measure mass and corrected volume in steam and liquid applications.
Specifications
Flow Meter Accuracy
± 0.70% of mass flow rate in water± 2% of mass flow in steam± 0.65% of volumetric rate for liquids (uncompensated)± 1% of volumetric rate for gas and steam (uncompensated)
DN15-300
Temperature Sensor Accuracy
± 2.2°F (1.2°C)
Turndown
38:1
Output
4-20 mA with HART® 5 or 74-20 mA with HART® 5 or 7 and Scalable Pulse OutputFOUNDATION; fieldbus ITK6 with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function block optional)
Wetted Materials
Stainless Steel – 316 / 316L and CF3MNickel Alloy – C-22 and CW2MHigh Temp Carbon Steel – A105 and WCBLow Temp Carbon Steel – LF2 and LCCDuplex UNS S32760 and 6AConsult factory for other wetted material options
Flange Options
ANSI Class 150 to 1500DIN PN 10 to PN 160JIS 10K to 40KFlanges are available in a variety of facingsConsult factory for additional flange ratings
Operating Temperatures
-330°F to 800°F (-200°C to 427°C)
Line Size
Flanged: 1½-in to 12-in (40 to 300 mm)Reducer: 2-in to 14-in (50 to 350 mm)
Features
· Automatically compensates for changing fluid density in steam and liquid applications
· Independently verify or replace the isolated, removable temperature sensor without breaking process seal
· Non-wetted sensor design increases plant availability by reducing shutdowns for maintenance or repair
· Compensate any liquid flow using up to five user-definable temperature and density pairs
· Perform advanced monitoring with flow/temperature variables that can be assigned to the 4-20 mA, digital or pulse output
· Improve reliability with diagnostics that constantly monitor temperature sensor health
· A standard internal signal generator included in every meter simplifies electronics verification
Common models
8800DF005SA1N1D1M5
8800DF010SA1N1D1M5
8800DF015SA1N1D1M5
8800DF020SA1N1D1M5
8800DF030SA1N1D1M5
8800DF040SA1N1D1M5
8800DF060SA1N1D1M5
8800DF080SA1N1D1M5
8800DF100SA1N1D1M5
8800DF120SA1N1D1M5
8800DW005SA1N1D1M5
8800DW010SA1N1D1M5
8800DW015SA1N1D1M5
8800DW020SA1N1D1M5
8800DW030SA1N1D1M5
8800DW040SA1N1D1M5
8800DW060SA1N1D1M5
8800DW080SA1N1D1M5
8800DW100SA1N1D1M5
8800DW120SA1N1D1M5
8800DR005SA1N1D1M5
8800DR010SA1N1D1M5
8800DR015SA1N1D1M5
8800DR020SA1N1D1M5
8800DR030SA1N1D1M5
8800DR040SA1N1D1M5
8800DR060SA1N1D1M5
8800DR080SA1N1D1M5
8800DR100SA1N1D1M5
8800DR120SA1N1D1M5
8800DD005SA1N1D1M5
8800DD010SA1N1D1M5
8800DD015SA1N1D1M5
8800DD020SA1N1D1M5
8800DD030SA1N1D1M5
8800DD040SA1N1D1M5
8800DD060SA1N1D1M5
8800DD080SA1N1D1M5
8800DD100SA1N1D1M5
8800DD120SA1N1D1M5