Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
EPS
JHE SERIES
USAGE
It is used for fire occurred of the buildings or other emergent situation,which is an emergency power device to provide center power for all kinds of lamps (such as metal halogen light ,sodium light)
Installation form: On the ground
Backup time: 90 minutes ,world type (the backu time could be deposited as designed)
Specification 0.6kw-10kw single phase ,input 220V,A.C.:(standard type) on ground: JHE-0.6KW,1KW,2KW,3KW,4KW,5KW,6KW,7KW,8KW,9KW,10KW
Notice: The standard backup time is 90 minutes as the newest national standard GB17945-2000<>.(Reason: light not only for evacuating people ,but also for rescuing)
This pruduct is used for fire control emergency light ,which belongs to fire control product ,according with the related rules issued by Ministry of Public Security bureau of fire protection.
ADVANTAGES:
Single designed ,convenient use
Low price ,save investment
Long life ,more than 20 years for the host machine
Battery maintained for free, cycle used for 300-500 times
Single operated , auto,alternation instanc with no man
The light degree kept stable ,work reliably ,simple maintenance
CHARACTERISTICS:
Adopt the newest IGBT invertion technique
Adopt center power supplied mode ,special lamps are not needed
Power supplied for emergency ,output in A.C. sine wave ,stable voltage ,stable frequency ,no noise, no harm to people
It could work tegether with fire protection linking ,computer monitor ,also could be controlled by fire protection center
Output by insulated inverter
LCD colorful display
Type explanation
JHE: Emergency Power Series KW: output rated capacity ,unit(KW)
Notice: The above output rated capacity KW is the power capacity when the power factor is 0.
Explanation: Please make sure the installation form ,input phase ,backup time ,fire control linking, output routes when you make order
EXPLANATION FOR EPS FRONT PANEL OF JHE SERIES
1. LCD colorful display
Display main voltage, output voltage ,output load ratio,battery voltage.,malfunction, output situation and battery unit situation
2. Button
Operation simply ,use conveniently
JHE-H SERIES
USAGE :
Emergency power supplied to the equipment of 380V/220V, such as fire protection facility or direct load or especially important load or fire protection emergency light load or other loads
Installation form: On the ground(standard power cupboard)
Backup time: 90-120 minutes,(standard),the backup time could be deposited as designed
Specification: 2KW-800KW
Specification: 2,4,6,8,10,15,20,25,30,45,55,75,95,110,130,160,180,200,220,250,280,315,400,500,630,800KW.These products are used for force load and fire protection emergency light
PRODUCT SUMMARY
JHE-H series EPS is of high technical green product with CPU controlled ,digital circuit and high integrated level electronic element ,which adopts module inverter produced by international famous manufactory ,and the newest fifth IGBT and invert technique .This product provides the second or third power for the direct load and especially important load facility and fire protection equipment or light
ADVANTAGES:
Static,no noise,no arranged cigarettes,no common damage ,no fire hidden danger
Switch over automatically without people
Save energy ,lose little power without emergency power supplied
Stable capability ,reliable safety and long using life
Comparing with generator,it’s comprehensive price is lower and capability price ratio is better.
CHARACTERISTICS:
Adopt the newest IGBT-invert module and high reliable integrated circuit
Modulate PWM technology in pulse width,four in one designm,constructer simplified
Supply power to any inductive or capacitive loads
Link with fire control,could realize building intelligent monitor by distance and fire protection
All the main componets adopt the high reliable well-known brand
Direction wires and parts are of fire-netardant and un-burnt characteristics
Notice: 1.JHE-H series is used for three phases, single phase or mixed type electrical equipment ,such as lift ,water pump ,air blower,light ,the screen of securities ,air conditioner ,office equipment ,finacial institution and so on.
2.Auto.fire protection linking device could be chosen.
3.When the JHE-H series EPS needs fire protection link,remote monitor and output with multi-loops ,please make sure before making order.
JHE-D SERIES
USAGE:
Only provide a variable three-phase emergency power system to fire protection facility with one power route or generator in direct load,in order to solve the emergency power supplied to the generator and the impact to the power supplying equipment when start.For example, water pump ,generator of the air blower or generator for other equipment.
Installation form: On the ground (standard power cupboard)
Backup time:120 minutes ,the backup time could be deposited as required
Specification:2,4,6,8,10,15,20,25,30,35,45,55,75,95,110,130,160,180,200,220,250,280,315,400,500KW and so on.
NOTICE:
1. JHE-D series just for pulling electric machine of one-to-one : JHE-D series itself with the changeable start function
2. Auto. Fire protection linking device could be chosen,JHE-D series itself with fire protection linking.
3. Choose JHE-D series power supply ,when the ratio between the output rated capacity of its detail specification and generator load is 1:1 for example, the load is 5KW ,when you choose this power supply should be JHE-D-5KW
4. The same capacity EPS ,the price of the JHE-D series is not higher than JHE series EPS
FOR EXAMPLE
1. JHE-D-10KW,changeable frequency emergency power supply ,output PWM wave, rated capacity 10KW
2. JHE-D-10KW/SHL,fire protection linking device,output rated capacity 10KW.
EPS INTELLIGENT MONITORING MANAGEMENT BY DISTANCE
Concentrate on controlling all the intelligent EPS power supply in the users’ net ,and save the related EPS information to the manage database (normal/emergency work status,output voltage ,charge malfunction,controller malfunction and so on) to relize operation without people.
The real-time backstage supporter intercepts intelligent EPS power supply malfunction warning (run in Service System mode),and send the related people the warning information by image ,voice,short letter of mobile ,BP calling ,e-mail and so on,which have been stored to the record database to be inquired by managers.
Monitor the work status of every EPS ,real-time dynamic information, detail information and history event record,and directly control it by distance.
Communication interface :RS232
Supporting net TCD/IP: TCP/IP,UDP.SNMP,HTTP(Wed Server),Telnet,ARP,could offer communication interface to building equipment of auto. Monitoring system.Soft environment : Support Windows 95,windows 98,windows NT,windows 2000,windows XP.
THE DESIGN STANDARD OF JONCHAN EPS
When power cut ,the regulating time is usually within 25ms to ensure the power supplied in time.
The load adaptive capacity is strong ,the loads conclude capacitive, inductive,mixing type and the capacitive of overload and resist impact are strong ,the ratio to the inductive load is 1:1
Output by several ways(three ways or four ways),prevent the malfunction caused by single output.
Have the functions of fire protection linking and distance-controlling signal,the hand-by and automatic functions could invert with each other.
The environment adopting capacity is strong ,which suits for various bad environment ,has the measures of preventing the high-low temperature,wet and hot ,smog ,dusty ,shake and the mouse bitting.
Long using life,battery charged fast and battery test and monitor functions.
CHOOSE THE CALCULATION METHOD FOR EPS CAPACITY
WHEN THE JHE SERIES OR JHE-H SERIES IS USED FOR THE EMERGENCY LIGHT LOADS:
1. When the load is fluorescent lamp of the electronic ballast,the calculation method of the EPS is: EPS capacity =the total capacity *1.1
2. When the load is ballast fluorescent lamp of the inductance ,the calculation method of the EPS is: EPS capacity =the total capacity *1.5
3. When the load is metal halogen light or sodium light ,the calculation method of the EPS is: EPS capacity =the total metal halogen light or metal sodium light *1.6
Notice: As the JHE series EPS emergency power supply belongs to single phase output ,not exist ,JHE-D series EPS belongs to three phases output ,although it’s lack of phase could be run ,the output capacity of each phase is one third of the rate capacity ,should not lean phase too much.
WHEN JHE-H SYSTEM EPS WITH MIXED LOAD
THE CALCULATION METHOD OF THE EPS CAPACITY
1.When EPS is used for several generators starting at the same time, the capacity of the EPS should obey the following principles: