We can produce according to customers’ requirements. At present, we can offer many kinds of logging cables with four temperature ratings of 150℃, 180℃, 232℃, 160℃. The diameter ranges from 5.6mm to 13.2mm.
6. Technical Parameters
W1BPP—11.8 7*0.56
1) O.D. of Cable: 11.8mm
2) O.D. Inner Armor: 9.28mm
3) Conductor DC Resistance: ≤34 Ω/km 20℃
4) Insulation Resistance: ≥500MΩ/km 20℃
5) Insulation Resistance of High Temperature: ≥2.5MΩ/km
6) A.C. Voltage Withstand Test: 1000V 50Hz 5min
7) Capacitance: ≤0.19 μ F/km 800-1000Hz
8) Shielding Performance: ≤5V
9) Breaking Strength: 86kN
10) Suggest Working Tension: 40kN
11) Minimum Sheave Diameter: 510mm
12) Stretch Coefficient: 0.85m/km/5kN
13) Working Temperature for Long-term: 125℃
14) Temperature Range: -30℃ ~ 150℃
15) Weight of Cables: 494kg/km
16) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.
Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.
W1BPP—11.8 7*0.56
1) O.D. of Cable: 11.8mm
2) O.D. Inner Armor: 9.28mm
3) Conductor DC Resistance: ≤34 Ω/km 20℃
4) Insulation Resistance: ≥500MΩ/km 20℃
5) Insulation Resistance of High Temperature: ≥2.5MΩ/km
6) A.C. Voltage Withstand Test: 1000V 50Hz 5min
7) Capacitance: ≤0.19 μ F/km 800-1000Hz
8) Shielding Performance: ≤5V
9) Breaking Strength: 86kN
10) Suggest Working Tension: 40kN
11) Minimum Sheave Diameter: 510mm
12) Stretch Coefficient: 0.85m/km/5kN
13) Working Temperature for Long-term: 232℃
14) Temperature Range: -50℃ ~ 260℃
15) Weight of Cables: 531kg/km
16) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.
Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.
5. Delivery Requirement:
The cable should be wrapped closely and tightly on the reel of which the diameter is not less than 50 times of the cable diameter, and there shouldn’t be any loose. Both ends of the cable should be sealed, and the extra cable of the reel should not be less than 300mm.
6. Storage and transportation:
6.1 The cable should be avoided outdoor storage, and the reel should be stand on the ground.
6.2 It is not allowed to throw the reel with cable from high place during the transportation, mechanical damage is neither allowed.
6.3 When packing while hanging, it is not allowed to hang several reels together. The cable reel should be placed stably on the track and ship and fixed well with proper method to avoid hitting and turning over.