Designation
|
Pair&AWG size
|
Conductor
(mm)
|
Insulation
(mm)
|
Cable Diameter
(mm)
|
Cable Weight
(kg/km)
|
Cat6 UTP PVC
|
4x2x23AWG
|
0.570
|
1.02
|
6.1
|
42
|
Cat6 UTP,LSZH
|
4x2x23AWG
|
0.570
|
1.02
|
6.1
|
44
|
Cat6 FTP,PVC
|
4x2x23AWG
|
0.585
|
1.15
|
7.2
|
46
|
Cat6 SFTP,PVC
|
4x2x23AWG
|
0.585
|
1.18
|
8.0
|
70
|
Cat6 FTP,LSZH
|
4x2x23AWG
|
0.585
|
1.15
|
7.2
|
48
|
Cat6 SFTP,LSZH
|
4x2x23AWG
|
0.585
|
1.18
|
8.0
|
73
|
Conductor DC resistance
(Ω/100m)
|
DC resistance unbalance
(%)
|
Mutual Capacitance
(pF/100m)
|
Capacitance Unbalance
(pF/100m)
|
≤7.32
|
≤2.5
|
≤5600
|
≤330
|
MHz
|
Impedance
(Ohm)
|
Attenuation
(dB/100m)
|
RL
(dB)
|
NEXT
(dB/100m)
|
PS-NEXT
(dB/100m)
|
ELFEXT
(dB/100m)
|
PS-ELFEXT
(dB/100m)
|
Delay
(ns/100m)
|
Skew
(ns/100m)
|
1
|
100±15
|
1.8
|
20
|
74
|
72
|
68
|
65
|
570
|
45
|
4
|
100±15
|
3.7
|
22
|
65
|
63
|
56
|
53
|
552
|
45
|
8
|
100±15
|
5.3
|
23
|
61
|
59
|
50
|
47
|
547
|
45
|
10
|
100±15
|
5.9
|
23
|
59
|
57
|
48
|
45
|
545
|
45
|
16
|
100±15
|
7.5
|
25
|
56
|
54
|
44
|
41
|
543
|
45
|
20
|
100±15
|
8.4
|
25
|
55
|
53
|
42
|
39
|
542
|
45
|
25
|
100±15
|
9.5
|
24
|
53
|
51
|
40
|
37
|
541
|
45
|
31.25
|
100±15
|
10.6
|
24
|
52
|
50
|
38
|
35
|
540
|
45
|
62.5
|
100±15
|
15.4
|
22
|
47
|
45
|
32
|
29
|
539
|
45
|
100
|
100±15
|
19.8
|
20
|
44
|
42
|
28
|
25
|
538
|
45
|
250
|
100±15
|
32.8
|
17
|
38
|
36
|
20
|
17
|
536
|
45
|