Property
|
Test Method
|
Typical Data
|
Inner Layer
|
||
Tensile strength
|
ASTM D 2671
|
≥12MPa
|
Elongation at break
|
ASTM D 2671
|
≥300%
|
Water absorption
|
ISO 62
|
<0.5%
|
Volume resistance
|
IEC 93
|
≥1.0´1014Ω.cm
|
Dielectric strength
|
IEC 243
|
≥20KV/mm
|
Density
|
ASTM D257-98
|
1.15g/cm3
|
External Layer
|
||
Tensile strength
|
ASTM D 638
|
≥14MPa
|
Elongation at break
|
ASTM D 638
|
≥300%
|
Water absorption
|
ISO 62
|
<0.5%
|
Volume resistance
|
IEC 93
|
<104Ω.cm
|
Density
|
ASTM D257-98
|
1.15g/cm3
|
Normal size
(mm)
|
As supplied (mm)
|
After recovered (mm)
|
nner insulation layer wall thickness
(mm)
|
Standard length
(m/spool)
|
|
Inside diameter
(min.)
|
Inside diameter
(Max.)
|
Total Wall thickness
(Nom.)
|
|||
BH-DWT 36/12
|
36
|
12
|
6.0
|
5.0
|
1000-1220
|
BH-DWT 45/15
|
45
|
15
|
6.0
|
5.0
|
1000-1220
|
BH-DWT 55/16
|
55
|
16
|
6.0
|
5.0
|
1000-1220
|
BH-DWT 62/18
|
62
|
18
|
6.5
|
5.5
|
1000-1220
|
BH-DWT 65/22
|
65
|
22
|
6.6
|
5.6
|
1000-1220
|
BH-DWT 73/26
|
73
|
26
|
6.6
|
5.6
|
1000-1220
|
BH-DWT 85/30
|
85
|
30
|
6.5
|
5.6
|
1000-1220
|
BH-DWT 100/38
|
100
|
38
|
6.6
|
5.6
|
1000-1220
|
BH-DWT 120/45
|
120
|
45
|
7.0
|
5.7
|
1000-1220
|
BH-DWT 140/50
|
140
|
50
|
7.0
|
5.7
|
1000-1220
|