Conventional Infrared Reflective Beam Smoke Detector

Products Introduce:

GST Conventional Reflective Beam Detector is a non-addressable reflective infrared beam smoke detector, which must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector.


With excellent built-in microprocessor, the detector has strong ability of analysis and judgment.

The detector can automatically carry out system adjustment, compensation
of variation of ambient data, and judgment of fire and fault through fixed algorithm, and indicate these states by LED and signal output terminals.

With new and reasonable design, attractive appearance, flexible adjustment and alignment method it’s easy to install and adjust.

The sensitivity of the detector can be set through hand held programmer in field, decreasing the demand for cleanliness of field conditions, and enlarging application areas.

The detector is applicable to historical buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons etc, as well as places where slight smoke particles exist.


微信图片_20210420172212.jpg

Products Features:

1. Wide operating voltage range, big monitoring areas.
2. Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
3. Built-in microprocessor enables intelligent judgment of fire alarm and fault.
4. The detector can calibrate automatically, which ensures that one person complete adjustment in short time. It’s also convenient to operate.
5. Self-diagnosis function can monitor the inner fault.
6. Automatic compensation for factors weakening received signals, such as dust contamination, positional excursion and ageing transmitter.
7. It has passive output contacts for fire alarm and fault.
8. Two sensitivity levels can be set in field.
9. The detector’s optical pathway is designed with strong anti-interference ability.
10. SMT processing technology.
11. Attractive and decent appearance.

Technical Specifications:

1. Power Voltage: 15VDC-28VDC

2. Power Current:   Commission current›20mA, Standby current›12mA, Alarm current›22mA

3. Fire Alarm and Fault Contact Output:

    Fire Alarm Relay: Contact capacity 28V/2A, which is normally open in normal state and closed in fire alarm state.
    Fault Relay: Contact capacity 28V/2A, which is normally open in normal state and closed in fault state.

4. Angle of Adjusting: -6°-+6°

5. Dependency Angle of Optical Pathway Orientation: 0.5¢

6. Sensitivity Level:
    Level 1: High sensitivity.

    Level 2: Medium sensitivity.

7. Indication of Detector State:
   
Commission: Green LED and Yellow LED are lit or flash in a certain way. See details in Section VI Commission.
   
Normal monitoring state: Red LED flashes periodically.
   
Fire: Red LED constantly illuminates, and Yellow LED turns off. Fire alarm should be cleared through powering up again.
   
Fault: Yellow LED constantly illuminates. The detector clears the fault signal automatically if the condition causing the fault disappears.
   
Optical pathway obscured totally: the detector first gives fault signal and turns on Yellow LED. 20s later, it alarms fire, illuminates Red LED and turns off Yellow LED.

   Note: In this case, it does not mean there is a fire. After the obscuration is removed, the detector clears fault signal automatically. Fire signal has to be cleared by powering up the detector again.

8. Operating Environment: Temperature: -10°C-+50°C , Relative Humidity 95%, non condensing

9. Monitoring Area: aximum monitoring area: 14*100=1400m2 , Maximum width: 14m

10. Length of Optical Pathway: 8m-100m

11. Protection Level:
      Under common environment, ingress protection rating is IP20.
      Under special environment, ingress protection rating is IP66 through glue-seal treatment.

12. Dimension: length: 206mm width: 95mm thickness: 95mm

13. Material and Color of Enclosure: ABS, Gray

14. Weight: 450g

15. Mounting Hole Spacing: Spacing for embedding: 158mm
     Spacings for surface mounting: 79mm€96mm