KRD30 series constant acceleration test
machine is used to evaluate when components, equipment and other electrical and
electronic products are subjected to constant acceleration environment (except
gravity), whether the structure adaptability and performance are good, and
obtain the units’ electrical parameters.
Advanced control system: Full-automatic
computer remote real-time control interface. The operator only needs to input
simple values to start the equipment and complete the acceleration test
accurately.
User-friendly display interface: the
control interface can display the test curve, tolerance and test time in real
time.
Powerful multi-acceleration continuous test
system: It can realize multi-level acceleration continuous test according to
the different requirements of the test sample.
Reliable protection measures: open circuit,
over-limit and over-speed protection can be realized.
Multiple control methods: In the case of
automatic control failure or no need of automatic control, the device can still
use manual control to complete the test.
Convenient and quick result output system:
After the test, the test report is automatically generated and printed out.
Technical Specifications
Parameters | KRD30-3 | KRD30-5 | KRD30-10 | KRD30-20 | KRD30-2M | KRD30-3M | KRD30-4M | KRD30-8M |
Max. Load (kg)/Position | 3×6 | 5×4 | 10×2 | 20×2 | 0.05×N | 0.04×N | 0.03×N | 0.02×N |
Acceleration (g) | 1~500 | 1~100 | 200~20k | 200~30k | 200~40k | 200~80k | ||
Max. Height for Specimen (mm) | 200 | 300 | / | |||||
Installation Radius (mm) | 200 | 500 | 130 | |||||
Test Direction | ±X, ±Y ±Z | |||||||
Launch/Stop Time (Min) | ≤3 | ≤5 | ||||||
Continues Worktime (Min) | 60 | 5 | ||||||
Acceleration Accuracy (%) | ≤3 | |||||||
Overall Dimension (mm) | 1100×1100×1200 | 1650×1350×1100 | 1000×1000×1200 | |||||
Collector Ring | Optional according to user requirements | / | ||||||
Weight (kg) | 1000 | 1500 | 1000 | |||||
Power Supply | AC380V±10% | |||||||
Control Mode | Fully closed-loop digital network (remote) automatic control + manual control | |||||||
Remarks | The current collector and the control precision can be in accordance the related standards or customer requirements | |||||||
Working Environment | Temperature Range 0~40℃, Humidity≤80% (no condense) | |||||||
Standards | MIL-STD-810F IEC68-2-7 MIL-STD-202 MIL-STD-750 MIL-STD-883 |