The KRD12 series shock test system is used
to measure and determine the horizontal impact resistance of a product or
package, and to evaluate the reliability and structural integrity of the test
unit in a horizontal impact environment. The system can perform conventional
half-sine wave, post-peak sawtooth wave, or trapezoid wave shock test to
realize the shock energy that the product is subjected to in the actual
environment, thereby improving the product or packaging structure.
Windows-based stable control system,
full-automatic remote-control interface
Pneumatic cylinder driving with advantages
of large driving force, short accelerating stroke, low cost and pollution free.
Trapezoidal guide posts: large supporting
force, good lubricity and full-automatic positioning table.
Automatic control of shock speed: the shock
overload value is achieved by adjusting the air pressure. After the cylinder
pressure is set, system will automatically control the shock speed with high
accuracy and good repeatability.
Adopts the high strength and hardness cast
aluminum table, which has high first-order resonance frequency, featured with
low noise and no clutter
The most reliable double-brake system:
effectively avoids secondary rebound collisions, more securely positioning the
table, and more reliably guarantees the safety of the operator.
Multiple waveforms: can perform
conventional half-sine waves, post-peak sawtooth waves, or trapezoid waves.
Easy installation: the device comes with a
base, due to short driving stroke of the pneumatic cylinder, the footprint is
small.
Integrated control & measurement
system: the system comes with a variety of waveform tolerance bands that comply
with the MIL-810 standard, automatically generates test reports after the test
is completed.
System scalability: the system can be designed
as a bidirectional shock according to user needs, saving test time more
effectively.
Technical Specifications
Model Parameters | KRD12-10 | KRD12-50 | KRD12-100 | KRD12-200 | KRD12-500 | KRD12-1000 | KRD12-2000 | KRD12-3000 | ||
Rated Load (kg) | 10 | 50 | 100 | 200 | 500 | 1000 | 2000 | 3000 | ||
Table Size (mm) | 200×200 | 500×500 | 600×600 | 800×800 | 1000×1000 | 1200×1200 | 1500×1500 | 2000×2000 | ||
Peak Acc. (g)
| Half-Sine | 10-5k | 10~1.5k | 10~1k | 10-800 | 10-600 | 10-500 | 10-200 | ||
Post-Peak Sawtooth | 10~200 | 10~100 | 10~50 | |||||||
Trapezoid | / | 15~200 | 15~200 | 15-100 | 15-60 | 15-60 | 15-50 | 30-50 | ||
Pulse Duration (ms) | Half-Sine | 0.3~40 | 1~60 | 1.5~60 | 2~60 | 2.5~60 | 3~60 | 6~60 | 8~60 | |
Post-Peak Sawtooth | 3~18 | 6~18 | ||||||||
Trapezoid | / | 3~18 | 6~18 | |||||||
Bump Waveform | Half sine wave | |||||||||
Bump Peak Acceleration (g) | 4-150 | 5-100 | ||||||||
Bump Pulse Duration (ms) | 2-30 | 3-30 | ||||||||
Bump Rate (Times/Min) | 10-120 | |||||||||
Overall Dimension (mm) | 3000×1150×850 | 3300×1150×850 | 3500×1200×850 | 3800×1300×850 | 4000×1450×850 | 4500×1650×850 | 5500×2000×850 | 6000×2200×850 | ||
Weight (kg) | 2000 | 2500 | 3000 | 4000 | 4500 | 5000 | 6000 | 7500 | ||
Environment | Temperature range 0 ~ 40℃; Humidity ≤ 80%, non-condense | |||||||||
Power | AC220V±10%, 50Hz | |||||||||
Air source | ≤1MPa | |||||||||
Floor | Foundation-free, the cement floor shall be leveled and the working distance of 800 ~ 1000mm shall be reserved around the equipment | |||||||||
Standard |