Property
|
States
|
Typical data
|
Test method
|
Tensile strength (MPa)
|
unaged
|
≥10.4
|
ASTM D2673
|
heat-aged
|
≥7.3
|
||
Ultimate elongation (%)
|
unaged
|
≥200
|
|
heat-aged
|
≥100
|
||
Voltage withstand(V)
|
unaged
|
2500V,60s,Pass
|
UL224
|
Dielectric strength (MV/m)
|
unaged
|
≥15
|
IEC 60243
|
Volume resistivity (Ω-cm)
|
unaged
|
≥1014
|
IEC 60093
|
Water absorption (%)
|
Unaged
|
≤1.0
|
ASTM D 570
|
Corrosion
|
Unaged
|
Pass
|
UL 224
|
Heat shock
|
Unaged
|
No cracks, flowing or dripping
|
UL 224
|
Low temperature flexibility
|
Unaged
|
No cracks
|
UL 224
|
Part No.
|
Supplied ID(mm)
|
After recovery(mm)
|
Package
|
|
ID
|
Wall Thickness
|
m/roll
|
||
BH-NIT-2X-2.4
|
3.0±0.2
|
≤1.3
|
0.45±0.10
|
50
|
BH-NIT-2X-3.2
|
3.5±0.2
|
≤1.5
|
0.45±0.10
|
50
|
BH-NIT-2X-4.8
|
5.0±0.2
|
≤2.3
|
0.45±0.10
|
100
|
BH-NIT-2X-6.4
|
6.5±0.2
|
≤3.0
|
0.56±0.10
|
100
|
BH-NIT-2X-9.5
|
10.5±0.3
|
≤5.0
|
0.56±0.10
|
100
|
BH-NIT-2X-12.7
|
12.5±0.3
|
≤6.0
|
0.56±0.10
|
100
|
BH-NIT-2X-19
|
19.0±0.5
|
≤9.0
|
0.70±0.10
|
100
|
BH-NIT-2X-25
|
26.0±0.5
|
≤12.5
|
0.90±0.15
|
50
|
BH-NIT-2X-38
|
41.5±1.0
|
≤20.0
|
1.00±0.15
|
50
|
Part No.
|
Supplied ID(mm)
|
After recovery(mm)
|
Package
|
|
ID
|
Wall Thickness
|
m/roll
|
||
BH-NIT-3X-2.4
|
≥2.4
|
≤0.8
|
0.55±0.10
|
50
|
BH-NIT-3X-3.2
|
≥3
|
≤1
|
0.55±0.10
|
50
|
BH-NIT-3X-4.8
|
≥4.5
|
≤1.5
|
0.60±0.10
|
100
|
BH-NIT-3X-6.4
|
≥6
|
≤2
|
0.60±0.10
|
100
|
BH-NIT-3X-9.5
|
≥9
|
≤3
|
0.75±0.10
|
100
|
BH-NIT-3X-12.7
|
≥12
|
≤4
|
0.75±0.10
|
100
|
BH-NIT-3X-19
|
≥18
|
≤6
|
0.85±0.10
|
100
|
BH-NIT-3X-25
|
≥24
|
≤8
|
1.00±0.20
|
50
|
BH-NIT-3X-38
|
≥39
|
≤13
|
1.50±0.20
|
50
|