ZPC127 Mine automatic transfer point touch sprinklers
USES:
Mainly used in the coal mine coal chute, coal bunker, coal and other places. The transfer point when coal dust produced by automatically
Sprinkler dust, clean air environment.
Performance characteristics:
When the belt lane on coal transportation, coal on the belt to touch to touch sensors, sensor sends the signal to the device's main box,
Drive electric ball valve is opened, the water transfer point, reduce the transfer point location of coal dust and dirt. Clean air environment. The sprinkler
State must have a continuous signal can, to prevent misoperation device, was launched only continuous signal is greater than 3 seconds after the device: when the signal to stop
After the device into the time delay, delay time 1 0 s in a 360 s adjustable delay shut down after the ball valve, stop the sprinkler.