HYZ-4 Isolation type positive pressure oxygen respirator
Product characteristics and USES:
HYZ4 isolation type positive pressure oxygen respirator (hereinafter referred to as the respirator) is a mine rescue team in the rescue work for personal respiratory protection device. Have a safe and reliable, comfortable, convenient operation, etc.
This apparatus is mainly used for mine rescue team members in the rescue work when in the respiratory protection from the harmful effects of the toxic or harmful gases.
Working principle:
1, when open the oxygen tanks, high pressure gas by pressure reducer into medium pressure gas. Medium pressure gas all the way through the demand valve, and the other all the way through quantitative gas hole into the low pressure in the system. When the body is medium intensity of labor, through quantitative oxygen supply to meet human demand for oxygen. With the increase of the human body the intensity of labor, when the pressure in the air to demand open valve, the valve spring clamp contact demand, demand valve open, the medium pressure gas inside air oxygen filling via the demand valve to meet human demand for oxygen. Positive pressure formation in the system, it is depend on the spring clamp compressed air bags and the oxygen to the effective demand, had always maintain positive pressure in the respiratory system.
2, airbags within the low pressure gas by suction cooling device, the suction, suction valve to the mask, man in a mask breath exhale through the exhalation valve, pipe, clean tank to the airbag; When the exhaled gas increase gradually, positive pressure spring is compressed. At the same time, the spring clamp position gradually rise. When the pressure in the respiratory system is reached (400 ~ 700) Pa, when the exhaust valve valve plates are open spring clamp. At this point, the exhaust valve to vent; When people breathe the amount from the L/min (10 to 50) changes, the scope of respiratory pressure always by demand valve, exhaust valve both automatic adjustment.
The main technical indicators:
Model HYZ - 4
Rated protective time 240 min
Oxygen bomb rated pressure 20 MPa
2.4 L oxygen tank volume
Oxygen capacity 440 l
Respiratory 30 l/min
Expiratory resistance pa 600 or less
Inspiratory resistance (0-600) Pa
Quantitative oxygen L/min (1.4 ~ 1.7)
Automatic supply oxygen p 80 l/min
The manual supplies oxygen acuity 80 l/min
Automatic supply valve opening pressure (10 ~ 245) Pa
Breathe in carbon dioxide concentration in 1% or less
Inhale oxygen concentration in > 21%
Alarm (4 ~ 6) MPa pressure
Alarm time (30 ~ 60) s
The intensity of sound level of 75 db (A) or higher
Overall dimensions 560 x 370 x 160 mm
weight 13 kg