DSH-261 Pensky-Martens Closed Cup Flash Point Tester

본문 바로가기


Home > Product > DSH-261 Pensky-Martens Closed Cup Flash Point Tester
Product
DSH-261 Pensky-Martens Closed Cup Flash Point Tester
Posting date : May 15, 2014
Membership
Free Member Scince Jul 18, 2013
Keyword :
Category
Contact
Candice
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
27-
Package & Delivery Lead Time
Detailed Description
A:Brief description: DSH-261 Pensky-Martens Closed Cup Flash Point Tester is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-martens Closed Cup) and ASTM D93. DSH-261 Pensky-Martens Closed Cup Flash Point Tester is suitable to make determination of the closed cup flash point of the petroleum products which flash point over 40℃. B:Main advantages: 1. This instrument is designed correspond with the requirements of GB/T261-2008. 2. The heating power is continuously and stepless adjustable. The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable. 3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean. 4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting units. C: Main technical specifications and parameters 1.Power supply:AC (220±10%)V, 50Hz. 2.Heating device::The heating power is continuously adjustable from 0 W to 600W. 3.Rate of sample’s heating up::(1~12)℃/min;Controllable and adjustable. 4.Electric stirring rate:(1)(90~120)turns/min,suitable to test procedure A. (2)(250±10)turns/min,suitable to test procedure B. 5.Standard oil cup:(1)Inner diameter: 50.7mm~50.8mm. (2)Depth: 55.7mm~56.0mm. (3)The scribed line depth of capacity of testing oil: 33.9mm~34.3mm. (4)Capacity of testing oil:about 70ml 6.Igniting device:(1)Igniting source: gas(or other civilian fuels,the same below) (2)Bore diameter: 0.8mm 7.Thermometer:Mercurial thermometer, correspond with GB/T261-2008 (1)Scale -5℃~110℃, division 0.5℃。 (2)Scale 20℃~150℃, division 1℃。 (3)Scale 90℃~370℃,division 2℃。 8.Ambient temperature:≤ 35℃ 9.Relative humidity:≤ 85% 10.Power consumption of overall unit:≤ 650W D:More Open Cup flash point tester: DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester DSHD-261 Pensky-Martens Closed Cup Flash Point Tester DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester DSHD-5208 Rapid Closed Cup Flash Point Tester DSHD-5208A Rapid High-temperature Closed Cup Flash Point Tester DSHD-5208D Rapid Low-temperature Closed Cup Flash Point Tester

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top