Fire Resistant Signal & Data Cables cat3 cat5 RS485

본문 바로가기


Home > Product > Fire Resistant Signal & Data Cables cat3 cat5 RS485
Product
Fire Resistant Signal & Data Cables cat3 cat5 RS485
Posting date : Nov 15, 2012
Membership
Free Member Scince Nov 15, 2012
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
S04-
Package & Delivery Lead Time
Detailed Description
Fire resistant FTP Cat3 Data Cables Fire Resistant UTP CAT5 Data Cables Fire Resistant RS485 Databus Cables APPLICATION The cables are desgined for structure wiring, compatible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in a one pair, two pair and four pair cable that will continue to transmit data even when being directly attacked by fire. STANDARDS Basic design to EN 50173 FIRE PERFORMANCE Circuit Integrity IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) System circuit integrity DIN 4102-12, E30 depending on lay system Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 CABLE CONSTRUCTION Conductors: Plain annealed copper wire, sized 0.64mm and solid according to IEC(EN) 60228 class 1. Insulation: PE wrapping with fire resistant silicone rubber compound type EI2 as per BS 7655-1.1. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two-pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layer. Overall Screen: Aluminum/polyester tape with tinned copper drain wire Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) CaBlE CONsTRUCTION Multipair Rs 485 Overall screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2 Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminum/polyester tape with tinned copper drain wire. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Double Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminium/polyester tape+copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Individual & Overall screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Overall Screen: Copper wire braid. outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall Screen: Copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20°C - +90°C Temperature range during installation (mobile state): -5°C - +60°C Minimum bending radius: 8 x Overall Diameter

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top