Fire Resistant mica sr insulation Instrumention Cables bs5308 en50288

본문 바로가기


Home > Product > Fire Resistant mica sr insulation Instrumention Cables bs5308 en50288
Product
Fire Resistant mica sr insulation Instrumention Cables bs5308 en50288
Posting date : Nov 15, 2012
Membership
Free Member Scince Nov 15, 2012
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
300/500V Mica+XLPE or SR Insulated & Overall Screened Multicore Instrumentation Cables 300/500V Mica+XLPE/SR Insulated & Overall Screened Multipair Instrumentation Cables 300/500V Mica+XLPE Insulated Individual And Overall Screened Instrumentation Cable 300/500V Braid-Screened Flexible Equipment Cables (Multipair) RE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OSCR/LSZH 300/500V Class 2 ) RE-2G(St)H...CI. FE 180 PH30 ( CU/SR/OSCR/LSZH 300/500V Class 2 ) RE-2X(St)HSWAH...CI. FE 180 PH30 ( CU/MGT+XLPE/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) RE-2G(St)HSWAH...CI. FE 180 PH30 ( CU/SR/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) RE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OSCR/LSZH 300/500V Class 2 ) RE-2G(St)H...CI. FE 180 PH30 ( CU/SR/OSCR/LSZH 300/500V Class 2 ) RE-2X(St)HSWAH...CI. FE 180 PH30 ( CU/MGT+XLPE/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) RE-2G(St)HSWAH...CI. FE 180 PH30 ( CU/SR/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) RE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/PSCR/OSCR/LSZH 300/500V Class 2 ) RE-2G(St)H PiMF...CI. FE 180 PH 30 ( CU/SR/PSCR/OSCR/LSZH 300/500V Class 2 ) RE-2X(St)HSWAH PiMF..CI. FE 180 PH 30 ( CU/MGT+XLPE/PSCR/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) RE-2G(St)HSWAH PiMF...CI. FE 180 PH 30 ( CU/SR/PSCR/OSCR/LSZH/SWA/LSZH 300/500V Class 2 ) aPPlIcaTIOn The cables are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fi re. sTanDaRDs Basic design to BS 5308/BS 7629-1 fIRe PeRfORMance Circuit Integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) Circuit Integrity with mechanical shock EN 50200(PH30); CEI 20-36/4-0 Circuit Integrity with mechanical shock & water spray EN 50200 annex E System circuit integrity DIN 4102-12, E30 depending on lay system Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 www.caledonian-cables.co.uk www.addison-cables.com Caledonian ADDISON 79 Fire Resistant Instrumention Cables Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Mica glass tape covered by extruded cross-linked XLPE compound or fire resistant silicone rubber compound type EI2 as per BS 7655-1.1. Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers. Overall Screen: Aluminum/polyester tape with 0.5mm2 screen (7/0.3mm) with tinned copper drain wire. Inner Sheath(optional):Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 Armouring(optional): Galvanized steel wire armour Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top