Maternal and child monitor PM-9000E+
ECG and heart rate / noninvasive blood pressure / blood oxygen / temperature / respiratory / fetal heart rate and uterine pressure / fetal movement mark / tape printing
features:
1,most precise for using the world famous module
2,the waveform is most clear for it uses the 8.4 inch colorful LCD TEF which has the strong brightness and high resolution.
3,rotating shuttle operation, and the screen can be used in both english and Chinese ,therefore, it is easy to learn and operate.
4,it can show the ECG at the same time
5,the ECG waveform can be replayed every five minutes and the ST part can be checked by itself.
6,it can memorize the data and catches the mobile waveform
7,the limit for the alarm can be set by yourself, and alarming both in sound and light.
8, it can be used for adults, children, and new born baby.
9,it is anti-interference for electric knife
10,it is widely used in internal medicine, surgery, obstetrics and gynecology department, Pediatrics, first-aid, ICU,and CCU.
It's parameters:
Size: 320mm×1800mm×270mm
Weight: 3.0kg
Screen: 12.1inch colorful liquid TFT LCD
Resolution: 800×600
Security standard: IEC601-1, UL2601
Heartbeat rate of fetus:
The probe: the nine wafer, the wide beam, work like pulse, high sensitivity
The power of Ultrasonic wave : lower than 1 MW / cm2
The frequency of it's work: 1.0MHZ
How to handle the signal: Digital signal processing unit
Maximum audio power output: 1.5w
Contraction stress:
The range of measurement: 20~100 pressure unit
The Ultrasonic output of the probe:
According to the rule set in 1992, the negative peak of sound pressure should be less than 1MPa, the Acoustic beam and the sound intensity should be less than 20 MW/cm2, the instant average peak of the sound intensity should be less than 100 MW/cm2. The sound intensity of this monitor is less than 1MW/cm2.
The GEL:
Viscous water-based compound, no harm to the skin, no allergy, stable,and anti-bacteria.
ECG:
Gain option: four gears including ×1 、×2 、×4、×0.5
Calibration signal: 1mV
Common mode signal suppression: greater than 70dB
Accuracy of heartbeat: ±5 times/minute
Scan rate:12.5 mm / S,25 mm / S,50 mm / S three standard file
ST segment detection: range(-2.0mV----+2.0mV)
Bandwidth:0.5HZ~100HZ
Lead: total lead, I, II, III, avF, avR, avL, V1-V6
Using standard: Conform to the standard of ANSI/AMI EC13-1992
Responding time:1s
Way of alarming: both in sound and light
Heart rate alarm preset range:upper limit,1~255times/minute
Lower limit,0~254times/minute
NIBP:
Technic:display waveform
Working mode:manual or automatic
Measuring unit:Mm hg / Kpa
Security for overpressure:double way for secure
Deviation between each period:choose in 2、5、10、15、30、