TGas-1031 Series Combustible, Toxic and Harmful Gas Transmitter

본문 바로가기


Home > Product > TGas-1031 Series Combustible, Toxic and Harmful Gas Transmitter
Product
TGas-1031 Series Combustible, Toxic and Harmful Gas Transmitter
Posting date : Nov 18, 2011
Membership
Free Member Scince Nov 18, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
S04-
Package & Delivery Lead Time
Detailed Description
Brief introduction TGas-1031 Series Combustible, Toxic and Harmful Gas Transmitter can continuously measure the concentration of site gas, and convert the concentration signal into 4-20mA output. It is extensively applied in petroleum, petrochemistry, chemical industry, gas, coal, metallurgy and electric power; safety detection in municipal administration, telecommunication and traffic tunnel construction; the place where combustible, poisonous and harmful gas might leak, such as gasholder station and special industrial factory building, etc. Main features  Two kinds of optional mode of power supply, including centralized busbar type and independent area type  High and low concentration alarm, performing real-time monitor to gas  Anti-poisoning type gas sensor with high sensitivity  Automatic modification of ageing curve of sensor, keeping constant alarm sensitivity  Function of automatic recognition of sensor trouble, function of high concentration gas above-norm of sensor  Function of automatic detection at starting up, and it has advanced function of self-diagnosis and self-reparing.  The calibrated concentration value is adjustable, facilitating users to set by themselves  When the sensor loses the function of monitoring alarm because of ageing, the detector is capable of automatic recognition and alarm, so as to effectively avoid missing report. Technical parameters Parameters Characteristics Detectable gas Combustible vapour of liquids, including methane, LPG, coal gas and gasoline, etc., as well as poisonous and harmful gas Measurement precision ±5%F.S Repeatability 2% Measurement range Refer to lectotype table for details Drift Zero drift: ±2%F.S Range drift: ±5%F.S Response time <30s(T90) Sampling method Diffusion Working environment Temperature: -30℃ to 60℃; humidity: below 85% (no coagulation) Remote control mode By the adjustment mode by infrared remote control, the detector can be adjusted without opening of cover 4-20mA output 4-20mA output corresponding to 0-100%, maximum load 800 ohms Alarm output The effective alarm is 1 point or 2 points; each alarm shall use SPDT electronic relay. Contact rating of alarm relay: Ohmic load: 5A@24Vdc or 120Vac or 240Vac Inductive load: 50VA Communication Communication description: two-wire system parallel RS485 protocol, 32 points at most Connection: Twisted pair with shield Distance: maximum 1000m Input voltage 24VDC±25%; power: 2W/way Certificate Explosion-proof grade: ExdIICT5 Protection class: IP66 Using cable ≥2.5mm2×4 Screened cable line, outside diameter of cable is required to be between 6mm- 9mm Lectotype table for detected gas (part gas) Model Range Low alarm setting range High alarm setting range Low alarm point High alarm point TGas-1031-FL 0-100%LEL 10%LEL-5%LEL 25%LEL-80%LEL 20%LEL 50%LEL TGas-1031-CO 0-500ppm 25ppm-100ppm 100ppm-500ppm 35ppm 200ppm TGas-1031-CO 0-1000ppm 25ppm-100ppm 100ppm-500ppm 35ppm 200ppm TGas-1031-H2S 0-100ppm 5ppm-15ppm 15ppm-30ppm 10ppm 15ppm TGas-1031-SO2 0-100ppm 1ppm-3ppm 3ppm-10ppm 2ppm 5ppm TGas-1031-CL2 0-20ppm 3ppm-10ppm 5ppm-15ppm 5ppm 10ppm TGas-1031-NH3 0-100ppm 20ppm-30ppm 30ppm-70ppm 25ppm 50ppm TGas-1031-NO 0-250ppm 20ppm-50ppm 50ppm-100ppm 25ppm 50ppm TGas-1031-NO2 0-100ppm 1ppm-2ppm 2ppm-5ppm 1ppm 2ppm TGas-1031-HCN 0-30ppm 5ppm-10ppm 10ppm-15ppm 5ppm 10ppm TGas-1031-PH3 0-1ppm 0.3ppm-0.5ppm 0.5ppm-0.8ppm 0.3ppm 0.6ppm Executed standards.(GB Standard is China National Standard) GB12358-2006 Gas monitors and alarms for workplace——General technical requirements GB3836.1-2000 Electrical apparatus for explosive gas atmospheres——Part 1 General requirements GB3836.4-2000 Electrical apparatus for explosive gas atmospheres—— Part 4 intrinsic safety "i" Explosion-proof mark: ExiaIICT3, it applies to 0 zone, 1 zone and 2 zone, the place that contains IIA-IIC category and T1-T3 group of explosive gas mixture, and is qualified to get explosion-proof conformity certificate through inspection by CQST.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.