ETCO2+SPO2 Patient Monitor 3.5 Inch

본문 바로가기


Home > Product > ETCO2+SPO2 Patient Monitor 3.5 Inch
Product
ETCO2+SPO2 Patient Monitor 3.5 Inch
Posting date : Jul 19, 2011
Membership
Free Member Scince Jul 19, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
Details: RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements. RSD2001A (standard)can monitor vital signals correlating to SpO2 and CO2. It integrates parameter measuring modules and display in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. The LCD of high resolution and bright LED display provides clear view of 2 waveforms,SPO2,PR,EtCO2,InCO2,Respiration rate. Specifications Display Messages: 2 Waveforms 2 indicator lights 2 Sound Mode corresponding Alarm Mode Device: 1 dot matrix LCD size: 3.5", resolution: 256X120 5 digital LED windows CO2 Method Infra-red Absorption Technique Measuring mode Sidestream Side-stream mode sampling gas flow rate 100, 150, 200 ml/Min (option) Measuring range CO2 0~99 mmHg INSCO2 0-99 mmHg AwRR 0~150 rpm Resolution CO2 1 mmHg INSCO2 1mmHg AwRR 1 rpm Accuracy CO2 2 mmHg,0 ~ 40 mmHg 5% of reading,41 ~ 76 mmHg 10% of reading, 77 ~ 99 mmHg AwRR 2 rpm Actualization interval about 1 Sec. Start-up Time: < 10 sec Rise Time: 240 msec (10% to 90 %) Delay Time: 1.12 seconds maximum with 7| length, 0.055|| ID. Sampling line at 175 ml/min Alarm range CO2 0 ~ 99 mmHg InsCO2 0 ~ 99 mmHg AwRR 0 ~ 150 rpm Suffocation Alarm Delay AwRR 10 ~ 40 Sec SpO2 Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% 2 % 0% ~ 69% unspecified Actualization interval about 1Sec Alarm Delay 10 Sec. Pulse Rate Measuring and Alarm Range 0~254bpm Resolution 1bpm Accuracy 2bpm Alarm Delay 10 Sec. Recall Trend Recall 8 to 96hours all parameters result. NIBP Measurement Recall 50 NIBP measurement data. Signal Interface Amplitude 1 V/mV Accuracy < 5 % Impedance 50 Signal Delay < 20 mS Battery Rechargeable 4.0 A/Hr 8.4V Li-ion battery Operating time under the normal use and full charge greater than 4 hours Operating time after the first alarm of low battery will be about 5 minutes Maximum charging time is 4 hours Environment Temperature Working 0 ~ 40 degrees Transport and Storage -20 ~ 60 degrees Humidity Working 30% - 85 % Transport and Storage 30% - 93 %(no coagulate) Altitude Working -500 to 4,600m Transport and Storage -500 to 13,100m Power Supply 100/250 VAC, 50/60 Hz (for adapter) Pmax=30VA Dissipation Working Less than 3W Power-off Less than 0.1W Size and Weight Size 318 x 152 x 264 mm Weight 5.5 kg Accessories Standard: Model number: RSD 2001A SPO2+ETCO2 1 main unit 1 SPO2 cable 10 ETCO2 tube 1 user manual Optional: Model number: RSD 2001B SPO2+NIBP Model number: RSD 2001C ETCO2 Model number: RSD 2001D SPO2 Model number: RSD 2001E SPO2+NIBP+ETCO2 Printer

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top