Aerial Bundled Power Cable

본문 바로가기


Home > Product > Aerial Bundled Power Cable
Product
Aerial Bundled Power Cable
Posting date : Jun 11, 2011
Membership
Free Member Scince May 09, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
Detailed Product Description ABC cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. 1KV, 10KV, etc. ABC cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. 1KV, 10KV, etc. Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE insulation, Aluminum Conductor Product Description 1. Application of Service Drop Cable: Service Drop Cable (ABC CABLE) is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve the safety and reliability of electrified wire netting. 2. Type of Service Drop Cable: Service Drop Cable (ABC CABLE) covers mainly three types: Duplex Service Drop Triplex Service Drop Quadruple Service Drop The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 3. Detailed Introduction of Service Drop Cable 3.1 Duplex Service Drop Applications To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. To be sued for service at voltage of 600 volts or less and at conductor temperature not to exceed 75 degree. Construction Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger. Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable amp cities Size (AWG) Stranding Insulation Thick(Mils) Size (AWG) Stranding Pated strength(ibs) inches XLPE PE XLPE PE AAC Neutral-messenger Pekingese 6 1 45 6 7 563 10.36 61 61 85 70 Collie 6 7 45 6 7 563 10.36 64 64 85 70 Dachshund 4 1 45 4 7 881 10.36 92 92 115 90 Spaniel 4 7 45 4 7 881 10.36 96 96 115 90 Doberman 2 7 45 2 7 1350 14.88 147 147 150 120 Malamute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160 3.2 Triplex Service Drop Applications To supply power from the utility’s lines to the consumer’s service head. For service at 600 Volts or less (phase to phase) at a conductor temperature of 75 degree maximum for PE insulation or 90 degree maximum for XLPE insulation. Construction Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger. Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable amp cities Size (AWG) Stranding Insulation. Thick(Mils) Size (AWG) Stranding Pated strength(ibs) inches XLPE PE XLPE PE AAC Neutral-messenger Patella 6 7 45 6 7 563 14.88 103 103 85 70 Oyster 4 7 45 4 7 881 14.88 154 154 115 90 Clam 2 7 45 2 7 1350 20.58 233 233 150 120 Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160 Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160 Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185 Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215 Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245 Nannynose 336.4 19 80 336.4 19 6146 38.79 1118 1118 420 325 3.3 Quadruple Service Drop Applications Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum, and insulated with PE or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable ampacities Size (AWG) Stranding Insulation. Thick(Mils) Size (AWG) Stranding Pated strength(ibs) inches XLPE PE XLPE PE AAC Neutral-messenger Clydesdale 4 1 45 4 7 881 20.58 198 198 100 80 Pinto 4 7 45 4 7 881 20.58 211 211 100 80 mustang 2 7 45 2 7 1350 25.42 318 318 135 105 Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140 Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160 Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185 Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210 Lippizaner 336.40 19 80 336.4 19 6146 38.79 1519 1519 370 280 Standards 1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors. 5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top