EX-100 Manual for Universal Length Instrument with Digital Processing

본문 바로가기


Home > Product > EX-100 Manual for Universal Length Instrument with Digital Processing
Product
EX-100 Manual for Universal Length Instrument with Digital Processing
Posting date : Apr 24, 2007
Membership
Free Member Scince Mar 27, 2007
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
Application The universal length instrument is applied for absolute and relative measurement. It features in high accuracy due to adopting Abbe comparative theory and a high precision measuring system. It is mainly used in measuring office of factories and various level measuring departments in metal machining industry, specially in machine manufacturing, bearing manufacturing, gauge manufacturing as well as precision tools manufacturing and instrument manufacturing etc industries. main subjects to be measured: 1. Shaft, hole, plug gauge, ring gauge, clip gauge, length bar, cone, cylindrical workpiece, lower-grade block gauge, workpiece with parallel planes etc. 2. Pitch diameter of internal thread, thread, thread ring gauge, thread plug gauge EX-100 instrument is equipped with a data processing system. This system consists of a computer and data processing software, digital display hardware. The measuring results can be output by a printer. 2. principal 2.1. The instrument is a contact-type measuring system, using scale as the measuring reference. According to Abbe theory, it is fixed in the center-line of the Abbe measuring shaft and the shaft is rectangle, there is no rotation during movement. The worktable has 5-axis freedom motions, with special accessories such as the inner measuring accessories, the electrical measuring accessories to measure workpiece internal/external dimensions. These functions are as same as traditional length instrument. 2.2 raster digital display system It includes a raster measuring system and a digital display system; 2.2.1 the raster measuring system consists of a scale and a reading head(Its theory is shown as Fig.1). a) Lighting system The raster reading head adopts an infrared light emitting diode as a light source. The light becomes parallel light on the scale surface with scales by a condenser. The infrared light emitting diode owns a high luminous efficiency with extremely low temperature and can work at low voltage and small current. It is compact, with long life and high reliability. b) Photoelectric translation The scale is a black-and white raster with 100 scales at each 1mm. The indicating raster is a tetrad division phases. When adjusting the former scales to parallel with the latter ones, the light gate (Mohr fringe) will occur during the both raster moving relatively due to light transmission effect and light screening effect. The silicon photocell at back of the indicating raster receives periodic change light flux which transfers into electric signals with 0°, 90, 180°and 270°phase differences. Then these signals are sent into the digital display system. 2.2.2 The digital display system is supported by an EDS100 fine digital display hardware and corresponding software(ED101).3.Specification 3.1 Measuring range(mm) a)External dimensions Absolute measuring range 0~100 Relative measuring range 0~700 b)nternal dimensions Using small-size measuring accessories (maximum penetrating depth 12, maximum wall thickness 50) 10~430 Using large measuring accessories (maximum penetrating depth 50, maximum wall thickness 85) Using electrical measuring accessories a)electrical measuring accessories 1~60 b)Universal measuring accessories 14~112 Thread measuring accessories a)head pitch diameter measuring Max. 200mm Pitch 0.5~6 b) Internal thread pitch diameter measuring Using small-size measuring accessories(mall diameter 13~ 30) Using large measuring accessories [small diameter from 31~(- wall thickness×2 Pitch 1~6 3.2 Reading mode and display value: dital display,isplay value 0.1μm 3.3 Measuring force(N) 0、1.5、2.5 3.4 Display value variability a)or external dimensions 2δ≤0.3μm b)or internal dimensions 2δ≤0.5μm 3.5 Instrument accuracy For external dimensions, accuracy better than: 0.5μm(20±0.2℃) For internal dimensions, accuracy better than: 1μm 3.6 Universal worktable a)Installation area approximately 160×60 mm2 b)light adjustment range (0~ 100)mm c)universal stroke 25 mm d)tilting around Y-axis ±3℃ e)worktable rotation ±4℃ f)limited load 10㎏ 3.7 Fitting dimension for inner diameter of the measuring cap-shaped accessories Φ6H7 3.8 Outer diameter for the rod fitting with the inner diameter of the measuring cap-shaped accessories Φ6g6 3.9(m)nstrument size Length×widt×height 990×90×50

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top