MA300A

본문 바로가기


Home > Product > MA300A
Product
MA300A
Posting date : Mar 08, 2011
Membership
Free Member Scince Mar 02, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
USE General radiography,Filter-ray-filter radiograph Unit Configuration Control, HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column ,Collimator MAIN CHARACTERISTICS 1Single-table/single-tube 2Rotary anode X-ray tube unit and tangential annular tube head 3Single-phase full wave rectification high-voltage generator 3Power voltage(v) radiograph kilovolt (KV).step-less control electric mechanism 4Filament stabilizer for X-ray tube unit and space charge compel mentor 5Radiograph volume KV 、mA and S. grading and interlock protection 6Adopt digital circuit timer. Grading according to R10 priority coefficient,(for more accurately controlling time) 7HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power 8Radiographic table can move in length an breadth 9The radiographic table. Column and vibrating grid are in a whole without ceiling and floorh rails bottom MIN TECHNICAL INDEXES ITEM CONTENTS INDEX Demand of power supply Capacity Two-phase 30KVA Voltage、Frequency 380V/220V ±10%50HZ ±0.5Hz Intemal resistance 2Ω(380V) 0.6 Ω(220V) power supply Adjustable range 380±10% at220V being adjustable continuously Radiograph Voltage 50-90KV 50-90KV being adjustable continuously current Small focus:50mA100mA,Big focus:50mA 100mA 200mA 300mA time 0.04~6.35s 23grades together grading a according to R10 coefficient High-voltage generator Capacity 20KVA(instantaneous) Max DC output voltage 125KV Max DC output current 300mA X-Ray tube Model XD51.20-40/125 Focus Small focus 1×1mm big focus2×2mm Radiographic table Length×width×height of bed surface 2000mm×665mm×700mm Moving range of bed surface 640mm in Length,200mmin breadth Ray-filter of table Travel in length ≥500mm Grid density N=28 Convergence distance f。=100cm Grid ratio r=8 Column of X-ray tube unit Moving Longitudinally along Radiographic table 1000mm or 1800mm Distance to friend as moving up and down (along column) 650~1800mm Rotary around the center of cross arm ±180° Rotary around the shaft line of X-ray annular tubes -10°~60°~ +120° Max size of cassette 356mm×432mm (14″×17″) Note: We will not make another notice if the contour of product and technical parameters will be changed

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top